Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Janz, Viktor* | Wassilew, Georgi I. | Perka, Carsten F. | Bartek, Benjamin
Affiliations: Orthopaedic Department, Charité - Universitätsmedizin Berlin, Berlin, Germany
Correspondence: [*] Corresponding author: Viktor Janz, Orthopaedic Department, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany. Tel.: +49 30 450615107; Fax: +49 30 450515909; E-mail:[email protected]
Abstract: BACKGROUND: It is currently unclear if an isolated exchange of the mobile components, in cases of periprosthetic joint infection (PJI), leads to a complete eradication of all bacteria or if residual bacteria remain attached to the retained components? OBJECTIVE: The purpose of this study was to investigate if bacteria only adhere to certain components or materials, or if they are ubiquitously distributed throughout the joint. METHODS: Two hundred and eighty-four patients undergoing revision total hip or total knee arthroplasty surgery were included in this retrospective cohort study. Synovial fluid cultures, periprosthetic tissue cultures, histological samples and sonicate fluid cultures (SFC) from the individual endoprosthetic components were acquired. The isolated bacterial species were recorded according to their endoprosthetic component of origin. RESULTS: In 72% of all cases with multiple SFC, the cultures were concordant with all samples being either homogenously negative or showing positive bacterial growth. The polyethylene (PE) components showed a significantly higher rate of bacterial isolation than the non-mobile components. All components and materials showed bacterial colonization, however between all other components or materials were not statistically significant. CONCLUSIONS: PE-components show a higher rate of bacterial isolation than other components. If an isolated bearing exchange is performed this should be supplemented by adequate antimicrobial therapy.
Keywords: Sonication, bacterial colonization, endoprosthetic components, PJI, total joint arthroplasty
DOI: 10.3233/THC-161257
Journal: Technology and Health Care, vol. 25, no. 1, pp. 137-142, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]