Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Workman, Craig D.a; b; c; * | Thrasher, T. Adama; b
Affiliations: [a] Department of Health and Human Performance, University of Houston, Houston, TX, USA | [b] Center for Neuromotor and Biomechanics Research, Houston, TX, USA | [c] Michael E. DeBakey VA Medical Center, Houston, TX, USA
Correspondence: [*] Corresponding author: Craig D. Workman, 3855 Holman Street, 104 Garrison Gym, Houston, TX 77204-6015, USA. Tel.: +1 713 743 5276; Fax: +1 713 743 9860; E-mail:[email protected]
Abstract: BACKGROUND: Researchers are measuring Reachable Workspace Volume (RWV) to assess the effects of various interventions on impaired upper extremity function. These measurement protocols have not been validated. OBJECTIVE: Assess the validity and reliability of two RWV protocols. METHODS: Fifteen able-bodied subjects and eight stroke subjects participated. Two RWV protocols (POLES and PLANES) were completed and compared with hemi-spheric volume estimations using the average reach in the Modified Functional Reach Test (MFRT). RWV, based on the movement of a single hand marker, was calculated using a 3D motion analysis system (Vicon, Centennial, CO, USA). Intraclass correlation coefficients (ICC) represented reliability, Pearson's linear correlation coefficient (r) between RWVs and MFRT represented validity, and p < 0.05 represented significant differences between the volumes. RESULTS: For the able-bodied subjects, the POLES protocol had excellent validity and excellent reliability, the PLANES protocol had good validity and excellent reliability, and both RWVs were significantly larger than estimated MFRT volume. In the stroke subjects, both protocols had good validity, excellent reliability, and RWVs which were significantly smaller than the estimated MFRT volume. CONCLUSIONS: Both measurement protocols provided valid and reliable measures of RWV. MFRT may underestimate RWV in able-bodied subjects, and overestimate RWV in stroke subjects.
Keywords: Stroke, hemiparesis, measurement, reachable workspace, validity, reliability
DOI: 10.3233/THC-161146
Journal: Technology and Health Care, vol. 24, no. 4, pp. 513-521, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]