Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chou, C.-H.a | Hwang, Y.-S.a | Chen, C.-C.b; * | Chen, S.-C.c | Chou, S.-W.d | Chen, Y.-L.e
Affiliations: [a] Department of Electronic Engineering and Graduate Institute of Computer and Communication Engineering, National Taipei University of Technology, Taipei, Taiwan | [b] Department of Management Information Systems, Hwa Hsia University of Technology, New Taipei City, Taiwan | [c] Department of Physical Medicine and Rehabilitation, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan | [d] Department of Applied Mathematics, Chinese Culture University, Taipei, Taiwan | [e] Department of Digital Technology Design, National Taipei University of Education, Taipei, Taiwan
Correspondence: [*] Corresponding author: C.-C. Chen, Department of Management Information Systems, Hwa Hsia University of Technology, No. 111, Gongzhuan Rd., Zhonghe Dist., New Taipei City 235, Taiwan. Tel.: +886 2 8941 5100 4110; E-mail:[email protected]
Abstract: BACKGROUND: A patient whose spinal cord was damaged due to accident may result in Tetraplegia or lose the ability to control his/her daily living environment. Currently, patients must use an invasive tool tongue movement, to help the patient communicate with the external environment. OBJECTIVE: This study designed a non-invasive tongue movement computer mouse system that allows the patient to use tongue movement to control a computer to communicate with the external environment. METHODS: Via a pressure sensor and assistive holder designed in this study, the pressure sensor can be moved using the assistive holder close to the mylohyoid muscle of the patient's lower jaw. The changes in pressure from the mylohyoid muscle are converted into computer mouse control signals to control a computer to communicate with the external environment. RESULTS: This study is based on ISO9241-Part 9 to design four kinds of training modes with varying difficulties. The data were collected from five able persons participating in the test over 7 days. The data includes throughput, path efficiency, test completion time and reaction time. The data verifies that the proposed system is stable and practical for persons with disabilities. CONCLUSION: The non-invasive computer mouse system for sensing tongue movement can completely breakthrough the limitations of the invasive tongue movement sensing system. This study uses non-invasive, simple tongue movements that correspond to the stretching and shrinking of the lower jaw mylohyoid muscle to control the computer mouse.
Keywords: Tongue drive system, assistive technology, human computer interface, non-invasive
DOI: 10.3233/THC-161137
Journal: Technology and Health Care, vol. 24, no. 3, pp. 401-408, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]