Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Moiduddin, Khajaa; b; c; * | Al-Ahmari, Abdulrahmana; b; c | Nasr, Emad S. Abouelc; d | Mian, Syed Hammada; b; c | Al Kindi, Mohammede
Affiliations: [a] Princess Fatima Alnijiris's Research Chair for Advanced Manufacturing Technology, King Saud University, Riyadh, Saudi Arabia | [b] Advanced Manufacturing Institute, King Saud University, Riyadh, Saudi Arabia | [c] Industrial Engineering Department, College of Engineering, King Saud University, Riyadh, Saudi Arabia | [d] Mechanical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt | [e] College of Dentistry, King Saud University, Riyadh, Saudi Arabia
Correspondence: [*] Corresponding author: Khaja Moiduddin, Princess Fatima Alnijiris's Research Chair for Advanced Manufacturing Technology (FARCAMT), King Saud University, Riyadh, Saudi Arabia. E-mail:[email protected]
Abstract: BACKGROUND: The customized mandible reconstruction has been a challenging task in maxillofacial surgery. Designing an implant taking into considering the surrounding bone contours is really critical. Various computer aided design techniques have been used in the designing the customized reconstruction implants, but nevertheless study on the comparison between these techniques is rarely used. OBJECTIVE: The objective of this study is to compare the mirroring and anatomical reconstruction design techniques used in the maxillofacial surgery and select the best design technique. METHODS: The three mandible bone defects-small (< 20 mm), medium (20 to 40 mm) and large (41 to 53 mm) tumors are reconstructed using the two reconstruction design techniques and compared to their accuracy, using a 3 dimensional (3D) implant design evaluation and part to Computer aided design (CAD) comparison using a Co-ordinate measuring machine (CMM). RESULTS: The analysis results indicate that the mirroring technique provides higher accuracy for the implant design as compared to the anatomical technique for the medium and large tumors at maxillofacial regions. In case of implant design in small tumors, the anatomical design provides perfect implant fitting. CONCLUSIONS: Based on the results, it is recommended to select the anatomy design technique only for small tumor regions and mirroring technique for medium and large tumors.
Keywords: CT scan, medical modelling, maxillofacial surgery, customized design implants, mirroring technique, anatomy reconstruction, co-ordinate measuring machine
DOI: 10.3233/THC-161136
Journal: Technology and Health Care, vol. 24, no. 3, pp. 377-389, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]