Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Recent Innovations on Biomedical Engineering
Guest editors: Wen-Hsiang Hsieh
Article type: Research Article
Authors: Lo, Rong-Chin | Huang, Wen-Lin* | Hsiao, Yu-Lin
Affiliations: Department of Electronic Engineer & Graduate Institute of Computer and Communication Engineering, National Taipei University of Technology, Taipei, Taiwan
Correspondence: [*] Corresponding author: Wen-Lin Huang, Department of Electronic Engineer and Graduate Institute of Computer and Communication Engineering, National Taipei University of Technology, Taipei, Taiwan. E-mail:[email protected]
Abstract: In recent years, positron emission tomography imaging (PET) and Computed tomography (CT) fusion images can be observed metabolic information, they can get a more accurate spatial information. People have to construct 3D models in the first place when they try to examine images from different angles. Once a cross-section which we want to inspect has been revealed, it can be observed from any angles. However, a issue people encounter in above-mentioned procedures is that they have to either process images fusion at the beginning and then reconstruct the 3D models with these images to generate section or rebuilt the 3D models with these images and fuse section images as the second step. The main objective of this research is to discriminate the divergences and merits between two types of procedures.This research discovers that two different procedures will exactly bring about dissimilar types of images. Therefore, this research particularly aims at the analysis of two images and evaluates the extent of fringe and remaining information. We calculates entropy and standard deviation of the images. Nevertheless, finding section on 3D models first and fusing images secondly will generate the images which retain more information.
Keywords: PET, CT, PET/CT fusion, 3D model
DOI: 10.3233/THC-151093
Journal: Technology and Health Care, vol. 24, no. s1, pp. S357-S367, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]