Issue title: Recent Innovations on Biomedical Engineering
Guest editors: Wen-Hsiang Hsieh
Article type: Research Article
Authors: Chang, Hsing-Chenga; * | Lin, Jung-Chinb | Lin, Shyan-Lunga | Chang, I-Nana | Lin, Chern-Shenga | Chen, Shi-Yaoa
Affiliations: [a] Department of Automatic Control Engineering, Feng-Chia University, Taichung, Taiwan | [b] Ph.D. Program of Electrical and Communications Engineering, Feng-Chia University, Taichung, Taiwan
Correspondence: [*] Corresponding author: Hsing-Cheng Chang, Department of Automatic Control Engineering, Feng-Chia University, 100, Wen-hwa Rd, Sea-twen, Taichung, Taiwan. E-mail:[email protected]
Abstract: In this study, an automatic microfluidic fluorescence-array measurement system is developed to detect the concentration of organic phosphate based on the luminol-hydrogen peroxide catalytic fluorescent mechanism. Not only sample quantity and cost can be reduced, but also detection time, accuracy and precision can be improved in the system. The system is composed of a CCD image module, a stepper motor with driver, a microfluidic fluorescence array, a background light elimination module, and a dynamic image-analyzed interface. The pesticides of chlorpyrifos and fenitrothion of organic phosphate are chosen as experimental samples. Only a 2.5 μ l quantity of sample is required to have a fast response time of 1.4 second. Experimental results show that the sensitivities of chlorpyrifos and fenitrothion are 1.88 V/ppm in the range of 0.166 ∼ 10 ppm with averaged error of 1.66% and 0.32 V/ppm in the range of 0.03 ∼ 10 ppm with averaged error of 1.68% respectively. The organophosphorus effective detection range of the developed system covers the legal prescription for pesticide residues.
Keywords: Organophosphorus measurement, centrifugal microfluidic, fluorescence-array, chlorpyrifos and fenitrothion
DOI: 10.3233/THC-151050
Journal: Technology and Health Care, vol. 24, no. s1, pp. S41-S48, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]