Abstract: Fifty-five patients undergoing routine chest CT were examined with four additional high resolution computed tomography (HRCT) slices to determine the proper milliampere-second settings for clinical HRCT of the lungs. The following technical factors were used: 1-mm collimation, 2-s scan time, 120 kVp and different milliampere settings (160 mA, 100 mA, 60 mA, 30 mA). On 47 out of 54 patients all the four HRCT cuts were at exactly the same level. These images were independently reviewed and assessed by three radiologists. The body mass index was calculated in order to determine the effect of the size of the patient on the milliamperage setting needed. The standard deviation of CT values of 1 mm and 10 mm slice was measured in a Plexiglas phantom with different mA settings. The slice thickness was measured with thermoluminescence dosimeter. In the phantom study the change of milliamperage from 160 mA to 30 mA at 120 kVp and 2 s increased standard deviation in CT units from about 4.6 to 8.9 in 1 mm slice and from about 2.9 to 4.3 in 10 mm slice. The Computed Tomography Dose Index (CTDI) values of both 1 mm and 10 mm slices at 160 mA–30 mA were approximately from 9 to 2 cGy (rad). In the patient study 1 mm HRCT scans with 120 kVp/100 mA/2 s showed the same diagnostic information as 120 kVp/160 mA/2 s scans for all patients regardless of size. If only the normal weight patients are considered, all the details were also well seen with 120 kVp/60 mA/2 s settings. In our study contrary to earlier reports 30 mA/2s was inadequate for diagnosis. We conclude that at 120 kVp medium-dose settings 60–100 mA/2 s or 120–200 mA s are in clinical practice appropriate for HRCT studies of the lungs in most patients.
Keywords: Lung, High resolution computed tomography, Imaging parameter, Absorbed dose, Computed Tomography Dose Index
DOI: 10.3233/THC-1993-1204
Journal: Technology and Health Care, vol. 1, no. 2, pp. 143-153, 1993
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]