Article type: Research Article
Authors: Arunachalam, K.a | Jacob, Lijin V.b | Kamalanand, K.b; *
Affiliations: [a] Department of Automobile Engineering, MIT Campus, Anna University, Chennai, India | [b] Department of Instrumentation Engineering, MIT Campus, Anna University, Chennai, India
Correspondence: [*] Corresponding author: K. Kamalanand, Department of Instrumentation Engineering, MIT Campus, Anna University, Chennai, India. E-mail: [email protected].
Abstract: Background:Analysis of liver tissue in normal and abnormal conditions is essential for disease research, medical device design and treatment planning. Currently cirrhosis and malignancies of liver are among the major causes of mortality, worldwide. Objective:The objective of this work is to design an efficient capacitive sensor using Finite Element Methods (FEM), for diagnosis of cirrhotic and malignant liver. Methods:In this work, 3D geometric FEM models (N = 120) of normal, cirrhotic and malignant liver were generated using Comsol 3.5a. A set of ‘E’ shaped metallic plates, each with a dimension of 1 × 1 × 1 mm were modeled and mounted on the developed liver models. Four different bio-compatible metals namely Gold, Silver, Palladium and Platinum were used for analysis. Further, the observed capacitance values were converted into voltage using a De Sauty's bridge circuit implemented using Proteus 8. Finally, the statistical significance of the results was analyzed using the ANOVA test. Results:Results demonstrate that the observed voltages show significant variations between different liver pathologies. The developed sensor characteristic was found to be linear and the sensitivity of the sensor was found to be high when platinum electrodes were used. The diagnostic ability of the developed sensors for the adopted biocompatible metals was found to be highly statistically significant (P < 0.001). Conclusions:The proposed sensor design is compact with small dimensions and can be placed in contact with the human liver using endoscopic techniques. Hence, the developed sensor may provide a minimally invasive technique for liver diagnosis. This study appears to be of high clinical relevance since modelling of normal and abnormal liver, as well as design of suitable sensors for identification of liver abnormalities is required for improving the present diagnostic techniques.
Keywords: Liver, finite element method, malignancy, cirrhosis, biocompatible metals, capacitive sensor
DOI: 10.3233/THC-140868
Journal: Technology and Health Care, vol. 22, no. 6, pp. 867-875, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]