Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hawi, Naela; * | Liodakis, Emmanouila | Musolli, Dautb | Suero, Eduardo M.a | Stuebig, Timoa | Claassen, Leifa | Kleiner, Carstenb | Krettek, Christiana | Ahlers, Volkerb | Citak, Musaa
Affiliations: [a] Trauma Department, Hannover Medical School (MHH), Hannover, Germany | [b] University of Applied Sciences and Arts, Department of Computer Science, Hannover, Germany
Correspondence: [*] Corresponding author: Hawi Nael, Trauma Department, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany. E-mail: [email protected].
Abstract: Background:Motion sensing input devices could provide a practical and low-cost alternative method for repeated range of motion measurements. This study aimed to assess the reliability, accuracy and time requirements of a motion sensing input device (Microsoft Kinect) for ROM measurements comparing it with goniometer based measurements and subjective estimation. Material and methods:Full ROM was measured in 14 shoulder and elbow joints using the different methods. The order was randomly selected and each movement was measured twice. The results were recorded in degrees and the time measured in seconds. Results:In general, there was a poor to moderate agreement between the Kinect system compared to the goniometer. There was a good agreement between the goniometer-based and the subjective technique. The Kinect-based technique showed excellent test-retest reliability. Conclusion:The Kinect system showed good test-retest reliability, but lower accuracy compared to goniometer-based measurements. Improvements in patient positioning and measurement protocol standardization must be made before its implementation in clinical practice.
Keywords: Motion detection, Kinect®, range of motion (ROM), goniometer
DOI: 10.3233/THC-140831
Journal: Technology and Health Care, vol. 22, no. 2, pp. 289-295, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]