Affiliations: [a] Radiation Safety Division, Nuclear Safety and Security Commission, Seoul, Korea | [b] Department of Radiological Science, Jeonju University, Jeonju, Korea | [v] Department of Interactive Media, Gachon University, Seongnam, Korea | [w] Department of Computer Science and Engineering, University of Information Technology and Sciences, Dhaka, Bangladesh | [x] Department of Computer Information Engineering, Sangji University, Wonju, Korea | [y] Department of Computer Software, Daelim University, Gyeonggi-do, Korea | [z] Division of Information and Communication, Baekseok University, Seoul, Korea
Correspondence: [*] Corresponding author: Jung-Keun Cho, Department of Radiological Science, Jeonju University, 303, Cheonjam-ro, Wansan-gu, Jeonju-si, Jeollabuk-do, Korea. Tel.: +82 63 220 3129; Fax: +82 63 220 2054; E-mail: [email protected].
Abstract: A glandular breast tissue is a radio-sensitive tissue. So during the evaluation of an X-ray mammography device, Average Glandular Dose (AGD) measurement is a very important part. In reality, it is difficult to measure AGD directly, Monte Carlo simulation was used to analyze the correlation between the AGD and breast thickness. As a result, AGDs calculated through the Monte Carlo simulation were 1.64, 1.41 and 0.88 mGy. The simulated AGDs mainly depend on the glandular ratio of the breast. With the increase of glandular breast tissue, absorption of low photon-energy increased so that the AGDs increased, too. In addition, the thicker the breast was, the more the AGD became. Consequently, this study will be used as basic data for establishing the diagnostic reference levels of mammography.
Keywords: Glandular, average glandular dose, Monte Carlo simulation, breast thickness
DOI: 10.3233/THC-140790
Journal: Technology and Health Care, vol. 22, no. 3, pp. 345-350, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]