Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Panzica, Martin; * | Suero, Eduardo M. | Omar, Mohamed | Bretin, Philipp | Krettek, Christian | Citak, Musa
Affiliations: Trauma Department, Hannover Medical School, Hannover, Germany
Correspondence: [*] Corresponding author: Martin Panzica, Trauma Department, Hannover Medical School, Carl-Neuberg-Straße 1, 30625 Hannover, Germany. Tel.: +49 511 532 2026; Fax: +49 511 532 5877; E-mail: [email protected].
Abstract: Background:Articular fracture reduction control remains a challenge even with the development of computer-assisted surgery. The Kyphoplasty procedure has shown advantages in treating vertebral fractures. One case report showed successful reduction of acetabular fractures using Kyphoplasty. Objective:This study examines the efficacy of this method in reducing depressed tibial plateau fractures. Methods:An insertion sleeve for the Kyphon balloon that could be calibrated by the navigation system was designed. A total of 30 test series in synthetic bone cubes were performed using fracture instruments of 2.5 mm, 5 mm and 15 mm diameter, respectively, creating three different depression fracture depths (mean 1.87 mm, 4.2 mm and 1.72 mm, respectively). The Kyphon balloon was used to attempt reduction of each fracture. The same setup was used for testing in five cadaveric tibia specimens. Results:After reduction, there was a remaining depression depth mean in the synthetic bone of 0.27 mm for the 2.5 mm instrument; 2.1 mm for the 5 mm instrument; and 1.72 mm for the 15 mm instrument. We could not adequately reduce depression fractures in cadaveric testing. Conclusions:The Kyphon balloon was accurately placed with the aid of navigation. The depth was the decisive factor in the reduction of the fracture and not the diameter. In cadavers, depression fractures greater than 5~mm depth could not be reduced with our setup.
Keywords: Navigation, tibial plateau fracture, kyphon, ISO C-3D, CAS
DOI: 10.3233/THC-130765
Journal: Technology and Health Care, vol. 22, no. 1, pp. 115-121, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]