Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Teslim, Onigbinde Ayodele; * | Olayinka, Adeoya | Michael, Egwu | Adesoji, Adedoyin Rufus | Oluwole, Awotidebe Taofeek
Affiliations: Medical Rehabilitation Department, College of Health Sciences, Obafemi Awolowo University, Ile-Ife, Osun State, Nigeria
Correspondence: [*] Corresponding author: Onigbinde Ayodele Teslim, Medical Rehabilitation Department, College of Health Sciences, Obafemi Awolowo University, Ile-Ife, Osun State, Nigeria. Tel.: +234 8062 5877 84; Fax: +234 8151 3128 76; E-mail: [email protected].
Abstract: Purpose:The main objective of this study was to determine the reliability and concurrent validity of using Modified Sphygmomanometer (sphyg) and body weighing scale to determine the magnitude of pressure and body weight change during digital spinal examination. Subjects:One hundred and twenty apparently healthy subjects were recruited. Methods:Weighing scale was used to measure the body weight of the investigator while Mercury sphygmomanometer was used to measure the pressure exerted. There was test re-test interval of 2 weeks. Data were analysed by descriptive statistic and Pearson product moment correlation. Results:The result showed that there was significant correlation between the weight change (WC) values obtained on the weighing scale on day 1 and 2 (r=0.91). Also, there was significant correlation between Pressure obtained in the sphygmomanometer on day 1 and 2 (r=0.94). Similarly, there was significant correlation between the WC and Pressure Change (PC), (r=−0.49). The participant's age, height, weight and BMI contributed significantly as predictors for both BWC and PC change respectively. Conclusion:This study concluded that weighing scale and Mercury sphygmomanometer are reliable and valid to determine the magnitude of pressure applied during DPAP.
Keywords: Reliability, sphygmomanometer, postero-anterior spinal pressure
DOI: 10.3233/THC-130741
Journal: Technology and Health Care, vol. 21, no. 4, pp. 397-405, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]