Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Suero, Eduardo M.; * | Citak, Mustafa | Njoku, Innocent U. | Pearle, Andrew D.
Affiliations: Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA
Correspondence: [*] Corresponding author: Eduardo M. Suero, MD, Hospital for Special Surgery, 535 E 70th St., New York, NY 10021, USA. Tel.: +1 212 774 2878; Fax: +1 646 797 8222; E-mail: [email protected].
Abstract: Purpose:There are a number of factors responsible for the longevity of unicompartmental knee replacements (UKR). These include the magnitude of postoperative alignment and the type of material used. The effect of component design and material on postoperative alignment, however, has not been explored. Materials and methods:We retrospectively reviewed 89 patients who underwent UKR with robotic guidance. Patients were divided into two groups, according to whether they had received an all-polyethylene inlay component (Inlay group) or a metal-backed onlay component (Onlay group). We explored the magnitude of mechanical alignment correction obtained in both groups. Results:Mean postoperative mechanical alignment was significantly closer to neutral in the Onlay group (mean=2.8°; 95% CI=2.4°, 3.2°) compared to the Inlay group (mean=3.9°; 95% CI=3.4°, 4.4°) (R2=0.65; P=0.003), adjusting for gender, BMI, age, side and preoperative mechanical alignment (Fig. 2). Further exploration revealed that the thickness of the tibial polyethyelene insert had a significant effect on postoperative alignment when added to the model (R2=0.68; P=0.01). Conclusion:Patients who received a metal-backed Onlay tibial component obtained better postoperative mechanical alignment compared to those who received all-polyethylene Inlay prostheses. The thicker overall construct of Onlay prostheses appears to be an important determinant of postoperative alignment. Considering their higher survivorship rates and improved postoperative mechanical alignment, Onlay prostheses should be the first option when performing medial UKR.
Keywords: Unicompartmental knee arthroplasty, metal-backed, all-polyethylene, robotic UKR, tibial component
DOI: 10.3233/THC-2012-00703
Journal: Technology and Health Care, vol. 21, no. 1, pp. 81-85, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]