Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Petri, M.a; * | Kruppa, C.a; b | Haasper, C.a | Broese, M.a | Liodakis, E.a | Krettek, C.a | Hurschler, C.c | Jagodzinski, M.a
Affiliations: [a] Trauma Department, Hannover Medical School, Hannover, Germany | [b] Trauma Department, Berufsgenossenschaftliche Universitätsklinik Bergmannsheil, Bochum, Germany | [c] Orthopaedic Surgery Department, Hannover Medical School, Hannover, Germany
Correspondence: [*] Address for correspondence: Dr. Maximilian Petri, Trauma Department, Hannover Medical School, Carl-Neuberg-Str. 1/OE 6230, D-30625 Hannover, Germany. Tel.: +49 511 532 2050; Fax: +49 511 532 5877; E-mail: [email protected].
Abstract: Ruptures of tendons and ligaments are a widely common injury in traumatology. The aim of the study was the development of a substitute tissue for such defects by methods of tissue-engineering. Human bone marrow stromal cells (hBMSC) were seeded on a decellularized bovine Achilles tendon and cultivated in a special bioreactor. We examined the influence of continuous perfusion on proliferation and biomechanical stability compared to static cultivation. Samples were taken on day 0, 7 and 14. Decellularized tendons were chosen as a negative control. Cell quantity was measured by the MTS-Test. Histology was analyzed by Haematoxylin-Eosin- and Pentachrome-coulouring. The cultivated tendons were tested biomechanically compared with the decellularized control group. MTS-Test revealed an increase of cell count of 7% in the static group and a decrease of 9% in the perfusion group. The perfusion group showed a stronger network of the fibroblasts and a higher amount of produced extracellular matrix. Biomechanical testing revealed significantly higher stability in the decellularized control group. This trial shows up new possibilities of managing defects of tendons and ligaments. The continuous perfusion in a bioreactor can improve the structure of the matrix seeded with hBMSC.
Keywords: Tissue engineering, cell culture, hBMSC, tendon, ligament
DOI: 10.3233/THC-2011-0621
Journal: Technology and Health Care, vol. 19, no. 4, pp. 223-231, 2011
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]