Article type: Research Article
Authors: Hasart, Olafa; * | Perka, Carstena | Christian, Koenigb; c | Asbach, Patrickc | Janz, Viktora | Wassilew, Georgi I.a
Affiliations: [a] Orthopaedic Department, Center for Musculoskeletal Surgery, Charité, Berlin, Germany | [b] Julius Wolff Institute, Berlin, Germany | [c] Department of Radiology, Charité-Universitätsmedizin, Berlin, Germany
Correspondence: [*] Address for correspondence: Olaf Hasart MD, Orthopaedic Department, Charité, Charitéplatz 1, 10117 Berlin, Germany. Tel.: +49 30 450515005; Fax: +49 30 450515922; E-mail: [email protected].
Abstract: Background:Precise identification of bony landmarks by use of pointer based navigation systems is influenced by thickness of soft tissue. Ultrasound-based navigation systems try to overcome the problems of positional deviation associated with soft tissue. The aim of the study was to investigate the influence of the BMI and the thickness of the soft tissue on the post-operative cup position and accuracy in the application of an ultrasound-based (US CAOS) and a pointer-based navigation system (P CAOS). Methods:82 patients received a hip replacement in minimally invasive surgery in two cohorts: US CAOS group: using ultrasound navigation (n = 39) and P CAOS group: using a pointer-based navigation (n = 43). Results:There was a significant difference in anteversion and anteversion error between the groups. In addition, we observed a significant correlation between the thickness of the presymphysial soft tissue and the anteversion error in both groups. We also detected a significant correlation between the anteversion error and the BMI in both groups. However, the absolute error in anteversion with increasing thickness of the soft tissue layer was slighter in the ultrasound-based group compared to pointer-based navigation. Conclusions:The accuracy of the ultrasound-based and pointer-based navigation systems are influenced by the BMI and the thickness of the soft tissue layer above the symphysis. However, ultrasound-based navigation seems to have advantages with thicker soft tissue layers, as seen in overweight and obese patients.
Keywords: Ultrasound-based navigation, pointer-based navigation, acetabular cup orientation, accuracy
DOI: 10.3233/THC-2010-0601
Journal: Technology and Health Care, vol. 18, no. 4-5, pp. 341-351, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]