Authors: Vanin, N.; * | Kenaway, M. | Panzica, M. | Jagodzinski, M. | Meller, R. | Krettek, C. | Hankemeier, S.
Affiliations: Department of Traumatology, Hannover Medical School, Hannover, Germany
Correspondence: [*] Address for correspondence: Nicolas Vanin, MD, Department of Traumatology, Carl-Neuberg-Str. 1, 30625 Hannover, Germany. Tel.: +49 511 532 2026; Fax: +49 511 532 5877; E-mail: [email protected].
Abstract: Introduction:The accuracy of preoperative planning of the size of total knee arthroplasty (TKA) in literature is only 50%. A problem of conventional radiographic planning with prothesis templates is varying enlargement of the radiographs. Digital planning and analysis of lower leg geometry revealed improved reliability compared to conventional techniques. The aim of the study was to evaluate the accuracy of digital planning of TKA with special planning software and calibrated radiographs and its interobserver reliability. Methods:In a prospective study the sizes of 30 TKA were planned with special software by a senior and a junior surgeon independently. For calibration a 30 mm reference ball on the radiographs was used. The planning was compared with the intraoperative chosen size of the TKA. Results:The correlation of the planned femoral component with the chosen size was 87% for the senior and 77% for the junior surgeon. The planning of the tibial component revealed a correlation for the senior surgeon in 90% and for the junior surgeon in 87%. Both component was planned correctly in 77% by the senior and in 63% by the junior surgeon. In 50% the planning of both surgeons matched completely the used prosthesis sizes. The linear κ coefficient of Cohen revealed a good agreement (0.65) and a high interobserver reliability. Discussion:Planning TKA with special planning software with digital, calibrated radiographs is more accurate compared to previous conventional planning. The senior surgeons planning of both component sizes matched in 77% the correct size. Clinical experience improves the accuracy of preoperative planning.
Keywords: Total knee arthroplasty, digital planning software, accuracy of planning, interobserver reliability
DOI: 10.3233/THC-2010-0598
Journal: Technology and Health Care, vol. 18, no. 4-5, pp. 335-340, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]