Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Citak, Mustafaa; * | Kendoff, Daniela | Gardner, Michael J.b | Oszwald, Markusa | O'Loughlin, Padhraig F.b | Olivier, Lucien C.c | Krettek, Christiana | Hüfner, Tobiasa | Citak, Musaa
Affiliations: [a] Trauma Department, Hannover Medical School, Hannover, Germany | [b] Orthopaedic Department, Hospital for Special Surgery, New York, NY, USA | [c] Department of Traumatology, Hand and Reconstructive Surgery, St. Josefs-Hospital Cloppenburg, Germany
Correspondence: [*] Address for correspondence: Mustafa Citak, MD, Trauma Department, Hannover Medical School, Carl Neubergstr. 1, 30625 Hannover, Germany. Tel.: +49 511 532 2050; Fax: +49 511 532 5877; E-mail: [email protected].
Abstract: Rotational malalignment after intramedullary nailing of femoral fractures is common, and symptoms occur when malrotation reaches 15°. Intraoperative measurement of rotation remains difficult, and multiple techniques have been described to address this. Regardless of the method used, rotational toggling may occur between the interlocking screws and the screw holes. We hypothesized that a clinically significant amount of rotation may occur with standard statically locked intramedullary nails. Mid-shaft diaphyseal fractures were created in 24 cadaveric femurs. Specimens were divided into 4 groups, and were stabilized with a statically locked intramedullary nail, a dynamically locked intramedullary nail, a compression plate, and a locking plate. Six additional femurs were kept intact as a control group. Specimens were mounted in a custom holding jig, which stabilized the constructs proximally and allowed free rotation distally. A computer navigation system was applied, and the femoral anteversion was measured. 4 N-m of internal and external torque was applied, and the change in version was measured. The statically locked nails rotated 14.2°, and the dynamically locked group rotated 15.7°. Both intramedullary nail groups showed significantly greater rotation than the plated groups. The compression plate specimens rotated 6.5° on average, and the locked plate group rotated 3.8°. Intramedullary femoral nailing with static or dynamic interlocking allows 15° of rotation of the femur around the nail under physiologic load. This may exacerbate intraoperative errors in determining and setting rotation. Angular stable plates or nails may minimize this problem.
Keywords: Femoral antetorsion, navigation, accuracy, malrotation, image guided surgery, femur fracture
DOI: 10.3233/THC-2009-0529
Journal: Technology and Health Care, vol. 17, no. 1, pp. 25-32, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]