Article type: Research Article
Authors: Gabay, Michaela; * | von Martius, Konstantinb
Affiliations: [a] University of Illinois at Chicago College of Pharmacy, Chicago, IL, USA | [b] Quintiles Consulting, Zuccalistr. 19, 80639 Munich, Germany
Correspondence: [*] Address for correspondence: M. Gabay, Director, Drug Information Group, University of Illinois at Chicago College of Pharmacy, 833 S Wood St, M/C 886, Chicago, IL 60612, USA. Tel.: +1 312 413 3977; Fax: +1 312 996 0448; E-mail: [email protected].
Abstract: Introduction:Comparative information related to the properties of intravenous containers is lacking. Information is important as healthcare providers weigh the strengths and weaknesses of various competing products. The aim of this study is to evaluate and compare three different intravenous containers: two closed-system fully collapsible bags that do not require external venting to empty (containers A and B) and one semi-rigid “bottle pack” that partially collapses unvented (container C). Methods:Through an observational study design, these containers were subjected to the following tests in order to evaluate their performance: determination of total and residual volume, air volume, admixture volume, presence of particulate matter, and a drop test. Results:The mean residual volume of container C was higher compared to containers A and B: between 0.6% and 11.7% with a closed administration set and between 0.7% and 10.8% with an open administration set. The mean air volume measured was increased relative to the nominal volume for container C. In addition, containers A and B exhibited no visible particulate matter after puncture, satisfied the drop test more frequently, and had relatively higher admixture volumes in comparison to container C. Conclusion:The results of these examinations reveal that containers A and B outperformed container C; however, caution must be used when interpreting these observational results in the clinical setting.
Keywords: Intravenous container, admixture, closed-system, open-system
DOI: 10.3233/THC-2008-16603
Journal: Technology and Health Care, vol. 16, no. 6, pp. 429-435, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]