Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Karmonik, Christofa; b; * | Bismuth, Jean X.b; c | Davies, Mark G.b; c | Lumsden, Alan B.b; c
Affiliations: [a] Department of Radiology, The Methodist Hospital Research Institute, Houston TX, USA | [b] Weill Medical College of Cornell University, New York, NY, USA | [c] Department of Cardiovascular Surgery, Methodist DeBakey Heart and Vascular Center, The Methodist Hospital, Houston, TX, USA
Correspondence: [*] Corresponding author: Christof Karmonik, 6565 Fannin MB1-002, Houston, TX 77030, USA. Tel.: +1 713 441 1583; Fax: +1 713 441 4660; E-mail: [email protected].
Abstract: Objective:To demonstrate the potential role of computational fluid dynamics (CFD) in therapeutic decision making for treatment of vascular pathologies of the human aorta. Methods:CFD simulations with patient specific geometries and patient-specific inflow boundary conditions obtained with magnetic resonance imaging were performed in three cases: 1) mobile thrombus in the aortic arch in a patient with ischemic stroke 2) acute type II B aortic dissection 3) abdominal aortic aneurysm repaired with an endoluminal graft. Blood flow pathlines, wall shear stresses (WSS), dynamic pressures, blood velocities and flow particle resident times were calculated. Results:Aortic thrombus was indicated as possible source of emboli by flowlines and elevated WSS (8% higher than average WSS at aortic wall) in case 1. This was not identified on conventional imaging. In case 2, the false lumen of the dissection showed elevated pressures and high blood velocities at systole but low pressures and stagnant flow at other times (blood velocity < 0.02 m/s and WSS < 0.1 Pa). Flow disturbances at the reentrance zone of blood from the false lumen were recognized. For case 3, elevated WSS at the landing zone of the endoluminal graft and at the right iliac section together with disturbed flow patterns and increased flow particle resident times were noted. Focal stenoses coincided with the flow disturbances. Measured velocity patterns were qualitatively in agreement with velocity patterns calculated with CFD. Conclusion:CFD simulations provide additional information of the hemodynamics in the diseased human aorta and may have potential in aiding the therapeutic decision making process.
Keywords: Computational fluid dynamics, human aorta, patient specific, type B II aortic dissection, endoluminal graft
DOI: 10.3233/THC-2008-16503
Journal: Technology and Health Care, vol. 16, no. 5, pp. 343-354, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]