Article type: Research Article
Authors: Lerch, Matthias | von Lewinski, Gabriela | Windhagen, Henning | Thorey, Fritz; *
Affiliations: Department of Orthopaedic Surgery, Hannover Medical School, Germany
Correspondence: [*] Address for correspondence: Dr. Fritz Thorey, MD, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany. Tel.: +49 511 5354 545; Fax: +49 511 5354 682; E-mail: [email protected].
Abstract: In femoral revision arthroplasty the orthopaedic surgeon frequently has to decide between performing an extended trochanteric osteotomy or trying to remove the femoral stem without an osteotomy and taking the risk of an intraoperative fracture. As this decision is often hard to make this study compared intraoperative femoral fractures during stem removal with extended trochanteric osteotomies in femoral revision arthroplasties. Twenty-eight femoral revision arthroplasties with an extended trochanteric osteotomy were compared with forty-five intraoperative fractures during revision hip arthroplasty. Preoperatively and after a follow-up of 2.8 years the patients were examined clinically and radiologically. We found no osteosynthesis related complication in the extended trochanteric osteotomy group, but six in the fracture group. Furthermore fewer re-revisions were observed in the osteotomy group. Additionally, a significant better clinical and radiological outcome can be found in the extended trochanteric osteotomy group compared to the fracture group. The results of this study suggest that a well conducted extended femoral osteotomy should be discussed in special cases to prevent femoral fractures during stem and cement removal which would probably lead to a poor postoperative outcome.
Keywords: Femoral revision arthroplasty, extended trochanteric osteotomy, intraoperative femoral fracture
DOI: 10.3233/THC-2008-16407
Journal: Technology and Health Care, vol. 16, no. 4, pp. 293-300, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]