Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Matthys, Koen S.a; * | Kalmar, Alain F.b | Struys, Michel M.R.F.b | Mortier, Eric P.b | Avolio, Alberto P.c | Segers, Patrickd | Verdonck, Pascal R.d
Affiliations: [a] School of Engineering and Design, Brunel University, London, UK | [b] Department of Anaesthesia, Ghent University Hospital, Ghent, Belgium | [c] Australian School of Advanced Medicine, Macquarie University, Sydney, NSW, Australia | [d] Institute Biomedical Technology IBiTech, Ghent University, Ghent, Belgium
Correspondence: [*] Address for correspondence: Dr. Koen S. Matthys, Brunel University West London, School of Engineering and Design, 1st Floor Howell Bld, Room H124, Uxbridge, Middlesex, UB8 3PH, UK. Tel.: +44 1895 267486; Fax: +44 1895 256392; E-mail: [email protected].
Abstract: Arterial tonometry is a non-invasive technique for continuous registration of arterial pressure waveforms. This study aims to assess tonometric blood pressure recording (TBP) as an alternative for invasive long-term bedside monitoring. A prospective study was set up where patients undergoing neurosurgical intervention were subjected to both invasive (IBP) and non-invasive (TBP) blood pressure monitoring during the entire procedure. A single-element tonometric pressure transducer was used to better investigate different inherent error sources of TBP measurement. A total of 5.7 hours of combined IBP and TBP were recorded from three patients. Although TBP performed fairly well as an alternative for IBP in steady state scenarios and some short-term variations, it could not detect relevant long-term pressure variations at all times. These findings are discussed in comparison to existing work. Physiological alterations at the site of TBP measurement are highlighted as a potentially important source of artifacts. It is concluded that at this point arterial tonometry remains not enough understood for long-term use during a delicate operative procedure. Physiological changes at the TBP measurement site deserve further investigation before tonometry technology is to be considered as an non-invasive alternative for long-term clinical monitoring.
Keywords: Arterial applanation tonometry, arterial blood pressure, non-invasive blood pressure monitoring
DOI: 10.3233/THC-2008-16304
Journal: Technology and Health Care, vol. 16, no. 3, pp. 183-193, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]