Issue title: Papers from the Regensburg Applied Biomechanics Symposium, June 2005
Guest editors: Joachim Hammerx and Michael Nerlichy
Article type: Research Article
Authors: Glinkowski, Wojciecha; b; * | Górecki, Andrzeja
Affiliations: [a] Department of Orthopaedics and Traumatology of the Locomotor System, “TeleOrto” Center of Excellence, Medical University, Lindleya 4, 02-005 Warsaw, Poland | [b] Department of Anatomy, Center of Biostructure Research, Medical University, Chałubińskiego 5, 02-005 Warsaw, Poland | [x] Mechanical Engineering Faculty, Laboratory for Materials Technology, University of Applied Science, Regensburg, Germany | [y] University Clinic, Department of Traumatology, Regensburg, Germany
Correspondence: [*] Corresponding author. E-mail: [email protected].
Abstract: Introduction:The use of noninvasive, acoustic methods like ultrasonometry is becoming increasingly interesting in the quantitative assessment of fracture healing. A reliable measurement technique has been described using ultrasonic transducers placed across the fracture gap. Ultrasonic image aiming is useful for accurate transducers location, on both sides of the gap. The study was designed to assess the clinical application of measurement of ultrasonic wave propagation through the fracture callus. Material and Methods:Contact testing was performed with a prototype ultrasonic bone tester UTTK-01 device. The measuring technique was validated experimentally on human long bones in vitro, as well on volunteers. Twenty four diaphyseal fractures of long bones were prospectively assessed. Transducers put on a fixed distance frame were properly placed with ultrasonographic focusing. Results:Average ultrasound propagation time was 1917 m/s. The measured values for fractures rose with time after injury. The average speed of sound measured between 10th and 21st day after fracture was 1200,85 m/s, after 7 to 8 weeks – 1559,35 m/s, after 12 weeks – 1640,64 m/s, after 16 weeks – 1735,72 m/s. Conclusions:We conclude that the technique for measuring long bone ultrasound velocity with ultrasonographic centering on the fracture gap allows repetitive positioning of ultrasonic transducers for measurement. Ultrasonic measurement of bone union may support or modify clinical decision. However, further studies are required to make the ultrasonometric method easier and more user friendly for clinical studies.
Keywords: Fracture healing, assessment, monitoring, cortical bone, quantitative ultrasound, ultrasonometry
DOI: 10.3233/THC-2006-144-514
Journal: Technology and Health Care, vol. 14, no. 4-5, pp. 321-333, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]