Issue title: Papers from the Regensburg Applied Biomechanics Symposium, June 2005
Guest editors: Joachim Hammerx and Michael Nerlichy
Article type: Research Article
Authors: Carvalho, L.a; b | Moreira, R.A.S.a | Simões, J.A.a; *
Affiliations: [a] Departamento de Engenharia Mecânica, Universidade de Aveiro, Portugal | [b] Instituto Politécnico de Saúde do Norte, Paredes, Portugal | [x] Mechanical Engineering Faculty, Laboratory for Materials Technology, University of Applied Science, Regensburg, Germany | [y] University Clinic, Department of Traumatology, Regensburg, Germany
Correspondence: [*] Address for correspondence: José António de Oliveira Simões, Departamento de Engenharia Mecânica, Universidade de Aveiro, 3810-193 Aveiro, Portugal. Tel.: +351 234 370830; Fax: +351 234 370953; E-mail: [email protected].
Abstract: The performance of a tooth replacement by using a dental implant relies on the mechanical and biological capability of the anatomical substitute to restore lost physiological functions. The design of an implant device able to properly replace the physiological tooth requires the study of the load transfer mechanism at the implant-bone interface and the understanding of the relevance of the periodontal ligament (PDL) in this mechanism. The PDL is a connective soft tissue that provides the fixation of the tooth in its bone-socket and the attenuation of occlusal loads. It also provides the ground cells that are involved in the remodelling process, induced by a change in the stress-strain pattern of the alveolar bone and also in the cementum of the tooth root. The purpose of this study was to determine the PDL effects on the dynamic load transfer mechanism, from the tooth to the alveolar bone, evaluating the equivalent dynamic stiffness of the ligament structure. A porcine fresh mandible with a tooth was used within the study, applying an experimental procedure to identify the dynamic transmissibility of the entire system. The transmissibility function provided information about the stiffness and damping of the PDL, information that can assist the design of an improved dental implant system.
DOI: 10.3233/THC-2006-144-526
Journal: Technology and Health Care, vol. 14, no. 4-5, pp. 457-465, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]