Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Wüster, C.a | de Terlizzi, F.b | Becker, S.a | Cadossi, M.b | Cadossi, R.b | Müller, R.c; *
Affiliations: [a] Department of Endocrinology, University of Heidelberg & Clinic for Endocrinology, Bahnhofplatz 2, D-55116 Mainz, Germany | [b] IGEA Biophysics Laboratory, Carpi (MO), Italy | [c] Orthopedic Biomechanics Laboratory, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, USA
Correspondence: [*] Address for correspondence: Ralph Müller, PhD, Institute for Biomedical Engineering, Swiss Federal Institute of Technology (ETH) and University of Zürich, Moussonstrasse 18, CH-8044 Zürich, Switzerland. Tel.: +41 44 632 4592; Fax: +41 44 632 1214; E-mail: [email protected].
Abstract: Introduction:Ultrasound studies evaluating bone tissue generally concentrate on two parameters – velocity and attenuation. This study aimed to determine whether ultrasound signal analysis techniques could provide additional information on the structural and mechanical characteristics of bone. Materials and methods:In vitro measurements were made on 26 left index fingers from human cadavers. Ultrasound measurements at the distal metaphysis and epiphysis; dual-energy X-ray absorptiometry of the whole phalanx; micro-computed tomography at the distal quarter of the phalanx (that is, the distal epiphysis and metaphysis), and mechanical three-point bending tests were performed. Univariate and multivariate linear regression techniques were used to analyze the results. Results:The ultrasound parameters, speed of sound and ultrasound peak amplitude correlated significantly with the three micro-computed tomography measures used to describe the characteristics of mineralized material (r=0.69–0.79, p<0.05). Low frequency ultrasound correlated significantly with micro-computed tomography parameters describing inter-trabecular or marrow spaces (r=0.68–0.78, p<0.05). Comparison of ultrasound parameters with geometric characteristics showed that while speed of sound and ultrasound peak amplitude were related to the cortical area, moment of inertia, and mechanical load (r=0.57–0.83, p<0.05), the amplitude of the fastest part of the ultrasound signal and full width at 80% maximum of the low frequency peak were related to the relative area of the medullary canal (r=0.40–0.43, p<0.05). Discussion:Quantitative ultrasound may provide information on structural, material and mechanical characteristics of bone to the same extent and even better than DXA Bone Mineral Density. These results have been obtained by a complete and exhaustive use of QUS technology in situ but under clinical conditions. The ultrasound parameters, correctly used and combined, seem to be effective tools for investigating bone tissue.
DOI: 10.3233/THC-2005-13605
Journal: Technology and Health Care, vol. 13, no. 6, pp. 497-510, 2005
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]