Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Klaessens, J.H.G.M. | Thijssen, J.M. | Hopman, J.C.W. | Liem, K.D.
Affiliations: Clinical Physics Laboratory, University Children's Hospital Nijmegen, 6500 HB Nijmegen, The Netherlands. Tel.: +31 24 3619061; E-mail: [email protected], [email protected]
Abstract: Objectives:in vitro assessment of the reproducibility and the optimal separation and position of the optodes in continuous wave (CW-) NIRS measurement of local inhomogeneities in absorption and/or scattering. Methods:a CW- NIRS system (OXYMON) was used with laser diodes at wavelengths of 767 nm, 845 nm, 905 nm, 945 nm and 975 nm. For practical considerations (dimensions of neonatal head) the measurements were performed on a cylindrical tissue-equivalent phantom (70 mm diameter of base material with μa=0.01mm−1 (800 nm) and μs′=1.00mm−1 (800 nm)), containing rods with 10 × absorption, or 10 × scattering, and 5 × both Monte Carlo simulations were carried out of a cylinder with transport scattering coefficient μs′=0.525mm−1 and absorption coefficient μa=0.075mm−1 and two optode positions. Results:reproducibility of repeated measurements (n=10) was ± 0.005 OD. Maximum OD in case of absorbing rod, and of absorbing + scattering rod was measured with optodes separated by 90° and rod position angle symmetrically (45°) in between. Minimum OD for these rods was obtained with optodes at 150° angle and rod position at 240° (i.e. relative to transmitting optode position at 0°). A second maximum OD was obtained at an optode angle 180° and rod position at 180°. Maximum OD (i.e. attenuation) for the scattering rod was at optode separation angle of 90° and rod at 0°. Minimum OD for this case was obtained with optode angle of 180° and rod positions around 80° and 280°. Maximum OD changes by absorbing rod were in the order of +0.12 OD and −0.04 OD, respectively. Simulations at an optode separation angle of 90° showed a spatial sensitivity path enclosing the rod position at maximum absorption found experimentally. Conclusions:when considering the phantom as a realistic geometrical model for the neonatal head, it can be concluded that the optode position at 90° angle would be optimal for detecting an inhomogeneity at 15 mm depth, i.e. the location of the periventricular white matter. Since the rods are relatively strongly different from the base material the question remains to be answered whether local ischemia, which might lead to irreversible brain damage, can be detected by CW-NIRS
Keywords: near infrared spectroscopy, phantom, optode, position, simulation
DOI: 10.3233/THC-2003-11105
Journal: Technology and Health Care, vol. 11, no. 1, pp. 53-60, 2003
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]