Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Matthys, Koen; * | Verdonck, Pascal
Affiliations: Institute Biomedical Technology IBITECH, Hydraulics Laboratory, Ghent University, Belgium
Correspondence: [*] Corresponding author: Koen Matthys, MScME, PhD Fellow, Biomedical Technology, IBITECH, Hydraulics Laboratory, Ghent University, Sint-Pietersnieuwstraat 41, B-9000, Gent, Belgium. Tel.: +32 9 264 89 26; Fax: +32 9 264 35 95; E-mail: [email protected].
Abstract: Arterial tonometry allows non-invasive and continuous registration of the arterial pressure waveform, by applanating (flattening) a superficial artery supported by bone with an external transducer. Inspired by ocular tonometry used for eye disease diagnosis, G.L. Pressman and P.M. Newgard built the first arterial tonometer in 1963, and derived a discrete, linear mechanical model. Accuracy remained poor until new sensor production techniques (silicon technology) arrived. G.M. Drzewiecki et al. published a second, more elaborate theoretical model for tonometer positioning in 1983. Few years later, the first modern tonometers were commercialised. Although the problems of sensor positioning, motion artefacts and calibration still exist, the tonometer has proven its usefulness in arterial compliance and hypertension studies. Attention should now go to analysis of the arterial pressure waveforms, and the combination with other signals (e.g. flow wave morphology) to allow a complete non-invasive haemodynamical description of the heart and the arterial tree.
Keywords: arterial, applanation, tonometry
DOI: 10.3233/THC-2002-10107
Journal: Technology and Health Care, vol. 10, no. 1, pp. 65-76, 2002
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]