Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Xi, Lelea; * | Yamamoto, Yukia | Mikata, Takashib | Shino, Motokia
Affiliations: [a] Department of Human and Engineered Environment Studies, Graduate School of Frontier Sciences, The University of Tokyo, Tokyo, Japan | [b] Shimoshizu National Hospital, Japan
Correspondence: [*] Corresponding author: Lele Xi, Department of Human and Engineered Environment Studies, Graduate School of Frontier Sciences, The University of Tokyo, Tokyo, Japan. E-mail: [email protected].
Abstract: Persons with Duchenne Muscular Dystrophy (DMD) usually have difficult in operating electric wheelchairs (EWs) using standard input device due to the lack of muscular power and the deformation of their hands. To solve this problem, various kinds of input devices are developed considering their physical limits. However, as the disease progresses, persons with severe DMD will gradually lose the ability to operate the developed input devices. In this study, we first made an investigation of physical functions for persons with severe DMD and found that functions of upper limb, especially functions of the fingers, tended to remain better in at least one-dimensional direction. A novel one-dimensional input device (1DID) was developed for persons with severe DMD based on a quantitative evaluation of the hand functions. Thus, this device can be operated using slight force and one-dimensional movement of a finger. Therefore, persons with severe DMD can adjust the straight and turning motion of an EW using two 1DIDs with the cooperative operation by two fingers. The validity of this device was demonstrated by evaluation experiments of 10 persons with severe DMD including those who do not have a proper input device. The evaluation results also show that the developed 1DID has the possibility to be widely used as a generic input device with computers for persons with severe disabilities.
Keywords: Electric wheelchair, Duchenne Muscular Dystrophy, hand function, one-dimensional input device, cooperative operation
DOI: 10.3233/TAD-190225
Journal: Technology and Disability, vol. 31, no. 3, pp. 101-113, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]