Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Pain, Helen | Jackson, S. | McLellan, D.L. | Gore, S.
Affiliations: Disability Equipment Assessment Centre, Rehabilitation Research Unit University of Southampton, Southampton General Hospital, E Level, Centre Block, Southampton SO16 6YD, UK. Tel.: +44 (0) 1703 794576; Fax: +44 (0) 1703 798539; E-mail: [email protected]
Abstract: Reducing back injury in health care workers is important, and the use of non-mechanical handling devices is recommended as one method of reducing risk of injury when manual handling is unavoidable. A user evaluation of 15 non-mechanical devices designed to help carers move dependent people (people who require assistance with transfers) in bed was conducted by the Medical Devices Agency, an Executive Agency of the Department of Health, UK. Sixty volunteer carers in hospitals, nursing homes and the community were randomly allocated to test devices in one of four groups: sliding sheets, short low friction rollers, long low friction rollers, miscellaneous handling devices. Opinions of the products were collected using questionnaires. The short low friction rollers were rated highest for perceived overall usefulness (75%) Envisaged use was appreciably lower than perceived usefulness. Several factors may account for this, and carers commented on the time taken to position the devices and the comfort for the dependent person. Such factors need to be addressed when training people in the use of such devices, to improve usage.
Keywords: assistive devices, manual handling, user evaluation, nursing, non-mechanical devices
DOI: 10.3233/TAD-1999-111-203
Journal: Technology and Disability, vol. 11, no. 1-2, pp. 13-19, 1999
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]