Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chen, Shunyia; b; | Zhang, Jiea; b; | Chen, Xiaohuac | Lin, Ruinand
Affiliations: [a] School of Mechatronic Engineering, Southwest Petroleum University, Chengdu, China | [b] Oil and Gas Equipment Technology Sharing Service Platform of Sichuan Province, Chengdu, China | [c] National Pipe Network Group Southwest Pipeline Co., Ltd., Chengdu, China | [d] Gas Management Office, PetroChina Southwest Oil & Gas Field Company, Chengdu, China
Correspondence: [*] Corresponding authors: Shunyi Chen. E-mail: [email protected]. Jie Zhang. E-mail: [email protected]
Abstract: This study examined the failure mechanism of fiber-wound composite pipe and determined the optimum winding angle. Simulation models of glass fiber-wound composite pipe were established. Failure factor of the reinforced layer of fiber-wound composite pipes under internal pressure, torsion, axial tension and bending load are investigated in conjunction with the three-dimensional Tsai-Wu failure criterion. The results show that the winding angle has a significant effect on the stress distribution of the reinforced layer. The inner layer of the reinforced layer is prone to failure under internal pressure. The outer layer of reinforcement layer under torsion is the easy failure position. The failure-prone layer under tensile load is related to the winding angle. The inner layer of the reinforced layer is prone to failure when the winding angle is less than 60°, and the outer layer is prone to failure when the winding angle is more than 60°. The outer reinforced layer is prone to failure under bending loads. When the winding angle is less than 50°, the easily failed failure position is on the inside of bending. When the winding angle is greater than 50°, the easily failed position is on the outside of bending. The smaller winding angle is conducive to improve the tensile, bending and torsion resistance of the composite pipe. The larger winding angle is beneficial for improving resistance to internal pressure. The optimal winding angle range for each load is different and multiple winding angles should be used in the design to obtain a higher overall load carrying capacity. The research results can provide a theoretical basis for the improved design, manufacture and evaluation of fiber-wound composite pipes.
Keywords: Fiber-wound composite pipe, winding angle, failure factor, bearing capacity
DOI: 10.3233/SFC-230012
Journal: Strength, Fracture and Complexity, vol. 16, no. 2, pp. 131-146, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]