Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Ohtonen, J.a; b; * | Lassila, L.V.J.a; c | Säilynoja, E.d | Varrela, J.e; f | Vallittu, P.K.a; f
Affiliations: [a] Department of Biomaterials Science, Institute of Dentistry, University of Turku, Turku, Finland | [b] City of Kotka Municipal Health Centre, Kotka, Finland | [c] Turku Clinical Biomaterials Centre – TCBC, Turku, Finland | [d] Stick Tech Ltd – GC Group, Turku, Finland | [e] Department of Oral Development and Orthodontics, Institute of Dentistry, University of Turku, Turku, Finland | [f] Oral Health Care, Turku Welfare Division, City of Turku, Finland
Correspondence: [*] Corresponding author: Jaana Ohtonen, Institute of Dentistry, Lemminkäisenkatu 2, FI-20520 Turku, Finland. Tel.: +358504679343. E-mail: [email protected].
Abstract: The aim of this study was to investigate the mechanical properties of fiber reinforced composite (FRC) wires with different polymer matrices and compare them with steel wires commonly used in orthodontic retention. Eight groups of the FRC wires (continuous unidirectional E-glass) and a control group of steel metal Penta One 0.0215′′ were tested with a 3-point bending test. The FRC wire groups consisted of two thicknesses of fiber rovings (300-tex and 600-tex) which were impregnated with a light-curing monomer resin system of bis-GMA/PMMA or bis-Mepp/dimetacrylate/prosphoric ester monomer. The bending was continued until breakage of the specimen or to the strain of 3 mm using a span length of 10 mm and cross-head speed 1.00 mm/minute. The data were analysed using analysis of variance (ANOVA). The maximum load values of the FRC wire groups varied between 1.3 and 20.0 N, and the control group was 2.4 N. Specimens of 600-tex groups had considerably higher load values than 300-tex groups. The load value of the control steel group was close to the load value of in the 300-tex groups. Bis-GMA/PMMA impregnated FRC demonstrated higher values of maximum load than bis-Mepp/dimethacrylate/prosphoric ester monomere resin impregnated FRC.
Keywords: FRC-wires, orthodontic retainer
DOI: 10.3233/SFC-160190
Journal: Strength, Fracture and Complexity, vol. 9, no. 3, pp. 187-196, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]