Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Shobirynia, Mohammada | Jalilzadeh Yengejeh, Rezaa; * | Derikvand, Ehsanb | Mohammadi Rouzbahani, Maryamc
Affiliations: [a] Department of Environmental Engineering, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran | [b] Department of Water Science, Shoushtar Branch, Islamic Azad University, Shoushtar, Iran | [c] Department of Environment, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran
Correspondence: [*] Corresponding author: Reza Jalilzadeh Yengejeh, Associate Professor, Department of Environmental Engineering, Ahvaz Branch, 61349-37333, 1915, Ahvaz, Iran. Tel.: +98 9124794322; E-mail: [email protected]; [email protected].
Abstract: The purpose of this study was the evaluation the Electro-Fenton (EF) and Photo Elecro-Fennton (PEF) efficiencies to remove of some pollution indicators from effluents of Acrylonitrile Butadiene Styrene (ABS) petrochemical industries affected by the operational parameters such as operation time, pH, current density, and concentration of H2O2. The EF and PEF reactors were made and a batch study was performed to optimize the operational parameters. The optimum operating conditions were determined as pH 5, reaction time 60 min, H2O2 concentration 50 mmol/lit and current density 20 mA/cm2 for EF process and pH 5, operation time 30 min, H2O2 concentration 25 mmol/lit, current density of 20 mA/cm2 for PEF process. The highest removal efficiencies of COD (chemical oxygen demand), turbidity, total kejaldahl nitrogen (TKN) and total suspended solids (TSS) by EF and PEF processes under optimal conditions were obtained 86.7, 88.1, 67.9 and 64.1% for EF and 92.4, 93.7, 70.5 and 67.2% for PEF process, respectively. The PEF process resulted in higher removal efficiencies than that of the EF process to remove COD and TKN especially. Also, the amount of energy consumption for EF and PEF were obtained 10.1 and 9.3 kW h/m3, respectively. The PEF process was more capable to remove the pollutants from wastewater, than the EF process in a shorter time and with a lower H2O2 concentration due to the presence of UV radiation, which causes the photocatalytic decomposition of organic pollutants.
Keywords: Photo-Electro-Fenton, petrochemical wastewater, organic pollutants, chemical oxygen demand, environment
DOI: 10.3233/MGC-230063
Journal: Main Group Chemistry, vol. 23, no. 2, pp. 133-144, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]