Article type: Research Article
Authors: Gong, Haoa | Liu, Ruib; c | Yu, Hengyongc | Lu, Jianpingd | Zhou, Ottod | Kan, Lijuane | He, Jia-Qiange | Cao, Guohuaa; *
Affiliations: [a] Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA | [b] Virginia Tech-Wake Forest School of Biomedical Engineering and Science, Wake Forest University Health Sciences, Winston-Salem, NC, USA | [c] Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, USA | [d] Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA | [e] Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Virginia Polytechnic Institute and State University, VA, USA
Correspondence: [*] Corresponding author: Guohua Cao, Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061, USA. Tel.: +540 2315686; Fax: +540 231 0970; E-mail: [email protected].
Abstract: BACKGROUND: The relatively high radiation dose from micro-CT is a cause for concern in preclinical research involving animal subjects. Interior region-of-interest (ROI) imaging was proposed for dose reduction, but has not been experimentally applied in micro-CT. OBJECTIVE: Our aim is to implement interior ROI imaging in a carbon nanotube (CNT) x-ray source based micro-CT, and present the ROI image quality and radiation dose reduction for interior cardiac micro-CT imaging of a mouse heart in situ. METHODS: An aperture collimator was mounted at the source-side to induce a small-sized cone beam (10 mm width) at the isocenter. Interior in situ micro-CT scans were conducted on a mouse carcass and several micro-CT phantoms. A GPU-accelerated hybrid iterative reconstruction algorithm was employed for volumetric image reconstruction. Radiation dose was measured for the same system operated at the interior and global micro-CT modes. RESULTS: Visual inspection demonstrated comparable image quality between two scan modes. Quantitative evaluation demonstrated high structural similarity index (up to 0.9614) with improved contrast-noise-ratio (CNR) on interior micro-CT mode. Interior micro-CT mode yielded significant reduction (up to 83.9%) for dose length product (DLP). CONCLUSIONS: This work demonstrates the applicability of using CNT x-ray source based interior micro-CT for preclinical imaging with significantly reduced radiation dose.
Keywords: Micro-CT, interior tomography, carbon-nanotube x-ray micro-CT
DOI: 10.3233/XST-160574
Journal: Journal of X-Ray Science and Technology, vol. 24, no. 4, pp. 549-563, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]