Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Meiser, J.a | Willner, M.b | Schröter, T.a | Hofmann, A.c | Rieger, J.d | Koch, F.a | Birnbacher, L.b | Schüttler, M.a; b | Kunka, D.a | Meyer, P.a | Faisal, A.a | Amberger, M.a | Duttenhofer, T.e | Weber, T.d | Hipp, A.b; f | Ehn, S.b | Walter, M.e | Herzen, J.b | Schulz, J.e | Pfeiffer, F.b | Mohr, J.a; *
Affiliations: [a] Institute of Microstructure Technology, Karlsruhe Institute of Technology Eggenstein-Leopoldshafen, Germany | [b] Department of Physics and Institute of Medical Engineering, Technische Universität München, Garching, Germany | [c] Institute for Applied Computer Science, Karlsruhe Institute of Technology, Karlsruhe, Germany | [d] Erlangen Center for Astroparticle Physics, Friedrich – Alexander – Universität Erlangen – Nürnberg, Erlangen, Germany | [e] Microworks GmbH, Karlsruhe, Germany | [f] Institute of Materials Research, Helmholtz-Zentrum Geesthacht, Geesthacht, Germany
Correspondence: [*] Corresponding author: Jürgen Mohr, Institute of Microstructure Technology, Karlsruhe Institute of Technology, 76344 Eggenstein-Leopoldshafen, Germany. Tel.: + 49 721 608 244 33; Fax:+ 49 721 608 24331; E-mail: [email protected]
Abstract: Grating based X-ray differential phase contrast imaging (DPCI) allows for high contrast imaging of materials with similar absorption characteristics. In the last years’ publications, small animals or parts of the human body like breast, hand, joints or blood vessels have been studied. Larger objects could not be investigated due to the restricted field of view limited by the available grating area. In this paper, we report on a new stitching method to increase the grating area significantly: individual gratings are merged on a carrier substrate. Whereas the grating fabrication process is based on the LIGA technology (X-ray lithography and electroplating) different cutting and joining methods have been evaluated. First imaging results using a 2×2 stitched analyzer grating in a Talbot-Lau interferometer have been generated using a conventional polychromatic X-ray source. The image quality and analysis confirm the high potential of the stitching method to increase the field of view considerably.
Keywords: X-ray phase contrast imaging, talbot interferometry, field of view, grating, LIGA, stitching
DOI: 10.3233/XST-160552
Journal: Journal of X-Ray Science and Technology, vol. 24, no. 3, pp. 379-388, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]