Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Pearson, Erika; c | Pan, Xiaochuana; b | Pelizzari, Charlesa; *
Affiliations: [a] Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL, USA | [b] Department of Radiology, The University of Chicago, Chicago, IL, USA | [c] Present Address: Princess Margaret Cancer Center, UHN, Toronto, ON, Canada
Correspondence: [*] Corresponding author: Charles Pelizzari, Radiation and Cellular Oncology, The University of Chicago, 5758S. MarylandAvenue MC9006, Chicago, IL 60637, USA. Tel.:+ 1 773-702-1688, Fax: +1 773-834-7299; E-mail: [email protected].
Abstract: BACKGROUND: Patient dose from image guidance in radiotherapy is small compared to the treatment dose. However, the imaging beam is untargeted and deposits dose equally in tumor and healthy tissues. It is desirable to minimize imaging dose while maintaining efficacy. OBJECTIVE: Image guidance typically does not require full image quality throughout the patient. Dynamic filtration of the kV beam allows local control of CT image noise for high quality around the target volume and lower quality elsewhere, with substantial dose sparing and reduced scatter fluence on the detector. METHODS: The dynamic Intensity-Weighted Region of Interest (dIWROI) technique spatially varies beam intensity during acquisition with copper filter collimation. Fluence is reduced by 95% under the filters with the aperture conformed dynamically to the ROI during cone-beam CT scanning. Preprocessing to account for physical effects of the collimator before reconstruction is described. RESULTS: Reconstructions show image quality comparable to a standard scan in the ROI, with higher noise and streak artifacts in the outer region but still adequate quality for patient localization. Monte Carlo modeling shows dose reduction by 10-15% in the ROI due to reduced scatter, and up to 75% outside. CONCLUSIONS: The presented technique offers a method to reduce imaging dose by accepting increased image noise outside the ROI, while maintaining full image quality inside the ROI.
Keywords: Region of interest imaging, image guidance, IGRT, cone-beam CT
DOI: 10.3233/XST-160550
Journal: Journal of X-Ray Science and Technology, vol. 24, no. 3, pp. 361-377, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]