Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Subtitle:
Article type: Research Article
Authors: Karimi, Seemeena; * | Martz, Harryb | Cosman, Pamelaa
Affiliations: [a] University of California, San Diego, La Jolla, San Diego, CA, USA | [b] Lawrence Livermore National Laboratories, Livermore, California, San Francisco, CA, USA
Correspondence: [*] Corresponding author: Seemeen Karimi, University of California, San Diego, La Jolla, San Diego, CA 92093, USA. Tel.: +1 617 953 1662; E-mail:[email protected]
Abstract: BACKGROUND: In aviation security, checked luggage is screened by computed tomography scanning. Metal objects in the bags create artifacts that degrade image quality. Though there exist metal artifact reduction (MAR) methods mainly in medical imaging literature, they require knowledge of the materials in the scan, or are outlier rejection methods. OBJECTIVE: To improve and evaluate a MAR method we previously introduced, that does not require knowledge of the materials in the scan, and gives good results on data with large quantities and different kinds of metal. METHODS: We describe in detail an optimization which de-emphasizes metal projections and has a constraint for beam hardening and scatter. This method isolates and reduces artifacts in an intermediate image, which is then fed to a previously published sinogram replacement method. We evaluate the algorithm for luggage data containing multiple and large metal objects. We define measures of artifact reduction, and compare this method against others in MAR literature. RESULTS: Metal artifacts were reduced in our test images, even for multiple and large metal objects, without much loss of structure or resolution. CONCLUSION: Our MAR method outperforms the methods with which we compared it. Our approach does not make assumptions about image content, nor does it discard metal projections.
Keywords: Metal artifacts, metal artifact reduction, computed tomography, luggage screening, constrained optimization
DOI: 10.3233/XST-150499
Journal: Journal of X-Ray Science and Technology, vol. 23, no. 4, pp. 435-451, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]