Article type: Research Article
Authors: He, Yua | Wang, Chengxianga; * | Yu, Weib; c; * | Wang, Jiaxid
Affiliations: [a] School of Mathematical Sciences, Chongqing Normal University, ChongQing, China | [b] School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning, China | [c] Key Laboratory of Optoeletronic and Intelligent Control, Hubei University of Science and Technology, Xianning, China | [d] College of Computer Science, Chengdu University, Chengdu, China
Correspondence: [*] Corresponding authors. Chengxiang Wang, School of Mathematical Sciences, Chongqing Normal University, ChongQing, 401331, China. E-mails: [email protected] and Wei Yu, School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning, 437100, China. E-mail: [email protected].
Abstract: BACKGROUND:Due to the incomplete projection data collected by limited-angle computed tomography (CT), severe artifacts are present in the reconstructed image. Classical regularization methods such as total variation (TV) minimization, ℓ0 minimization, are unable to suppress artifacts at the edges perfectly. Most existing regularization methods are single-objective optimization approaches, stemming from scalarization methods for multiobjective optimization problems (MOP). OBJECTIVE:To further suppress the artifacts and effectively preserve the edge structures of the reconstructed image. METHOD:This study presents a multiobjective optimization model incorporates both data fidelity term and ℓ0-norm of the image gradient as objective functions. It employs an iterative approach different from traditional scalarization methods, using the maximization of structural similarity (SSIM) values to guide optimization rather than minimizing the objective function.The iterative method involves two steps, firstly, simultaneous algebraic reconstruction technique (SART) optimizes the data fidelity term using SSIM and the Simulated Annealing (SA) algorithm for guidance. The degradation solution is accepted in the form of probability, and guided image filtering (GIF) is introduced to further preserve the image edge when the degradation solution is rejected. Secondly, the result from the first step is integrated into the second objective function as a constraint, we use ℓ0 minimization to optimize ℓ0-norm of the image gradient, and the SSIM, SA algorithm and GIF are introduced to guide optimization process by improving SSIM value like the first step. RESULTS:With visual inspection, the peak signal-to-noise ratio (PSNR), root mean square error (RMSE), and SSIM values indicate that our approach outperforms other traditional methods. CONCLUSIONS:The experiments demonstrate the effectiveness of our method and its superiority over other classical methods in artifact suppression and edge detail restoration.
Keywords: CT reconstruction, limited-angle CT, image quality assessment, multiobjective optimization
DOI: 10.3233/XST-240111
Journal: Journal of X-Ray Science and Technology, vol. 32, no. 5, pp. 1209-1237, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]