Abstract: BACKGROUND:Projection Domain Decomposition (PDD) is a dual energy reconstruction method which implements the decomposition process before image reconstruction. The advantage of PDD is that it can alleviate beam hardening artifacts and metal artifacts effectively as energy spectra estimation is considered in PDD. However, noise amplification occurs during the decomposition process, which significantly impacts the accuracy of effective atomic number and electron density. Therefore, effective noise reduction techniques are required in PDD. OBJECTIVE:This study aims to develop a new algorithm capable of minimizing noise while simultaneously preserving edges and fine details. METHODS:In this study, a denoising algorithm based on low rank and similarity-based regularization (LRSBR) is presented. This algorithm incorporates the low-rank characteristic of tensors into similarity-based regularization (SBR) framework. This method effectively addresses the issue of instability in edge pixels within the SBR algorithm and enhances the structural consistency of dual-energy images. RESULTS:A series of simulation and practical experiments were conducted on a dual-layer dual-energy CT system. Experiments demonstrate that the proposed method outperforms exiting noise removal methods in Peak Signal-to-noise Ratio (PSNR), Root Mean Square Error (RMSE), and Structural Similarity (SSIM). Meanwhile, there has been a notable enhancement in the visual quality of CT images. CONCLUSIONS:The proposed algorithm has a significantly improved noise reduction compared to other competing approach in dual-energy CT. Meanwhile, the LRSBR method exhibits outstanding performance in preserving edges and fine structures, making it practical for PDD applications.
Keywords: Dual-energy computed tomography, projection domain decomposition, Low rank, similarity-based regularization
DOI: 10.3233/XST-230248
Journal: Journal of X-Ray Science and Technology, vol. 32, no. 3, pp. 549-568, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]