Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Ma, Yuea; b | Liu, Dexiangb | Hua, Jianfeib; * | Lu, Weib; c; *
Affiliations: [a] Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China | [b] Department of Engineering Physics, Tsinghua University, Beijing, China | [c] Beijing Academy of Quantum Information Sciences, Beijing, China
Correspondence: [*] Corresponding authors: Jianfei Hua and Wei Lu, Department of Engineering Physics, Tsinghua University, Beijing, 100084, China. E-mail: [email protected] (JH) and [email protected] (WL).
Abstract: BACKGROUND:Inverse Compton scattering (ICS) source can produce quasi-monoenergetic micro-focus X-rays ranging from keV to MeV level, with potential applications in the field of high-resolution computed tomography (CT) imaging. ICS source has an energy-angle correlated feature that lower photon energy is obtained at larger emission angle, thus different photon energies are inherently contained in each ICS pulse, which is especially advantageous for dual- or multi-energy CT imaging. OBJECTIVE:This study proposes a dual-energy micro-focus CT scheme based on the energy-angle correlation of ICS source and tests its function using numerical simulations. METHODS:In this scheme, high- and low-energy regions are chosen over the angular direction of each ICS pulse, and dual-energy projections of the object are obtained by an angularly-splicing scanning method. The field-of-view (FOV) of ICS source is extended simultaneously through this scanning method, thus the scale of the imaging system can be efficiently reduced. A dedicated dual-energy CT algorithm is developed to reconstruct the monoenergetic attenuation coefficients, electron density, and effective atomic number distributions of the object. RESULTS:A test object composed of different materials (carbon, aluminium, titanium, iron and copper) and line pairs with different widths (15/24/39/60 μm) is imaged by the proposed dual-energy CT scheme using numerical simulations, and high-fidelity monoenergetic attenuation coefficient, electron density, and effective atomic number distributions are obtained. All the line pairs are well identified, and the contrast ratio of the 15 μm lines is 22%, showing good accordance with the theoretical predictions. CONCLUSIONS:The proposed dual-energy CT scheme can reconstruct fine inner structures and material compositions of the object simultaneously, opening a new possibility for the application of ICS source in the field of non-destructive testing.
Keywords: Inverse compton scattering X-ray source, dual-energy computed tomography, laser plasma accelerator
DOI: 10.3233/XST-230093
Journal: Journal of X-Ray Science and Technology, vol. 31, no. 6, pp. 1227-1243, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]