Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Xu, Min | Wang, Lijia; *
Affiliations: School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
Correspondence: [*] Corresponding author: Lijia Wang, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China. E-mail: [email protected].
Abstract: BACKGROUND:Cardiac cine magnetic resonance (CCMR) imaging plays an important role in the clinical cardiovascular disease (CVD) examination and evaluation. OBJECTIVE:To accurately reconstruct the displacement field and describe the motion of the left ventricular myocardium (LVM), this study proposes and tests a new approach for tracking myocardial motion of the left ventricle based on a biomechanical model. METHODS:CCMR imaging data acquired from 103 patients are enrolled, including two simulated and 101 clinical data. A non-rigid image registration method with a combination of a thin-plate spline function and random sample consensus is used to recover the observed displacement field of LVM. Next, a biomechanical model and a material matrix are introduced to solve the dense displacement field of LVM using a finite element framework. Then, the tracking precision and error of results for the two groups are analyzed. RESULTS:Displacement results of the simulated data show correlation coefficient≥0.876 and mean square error≤0.159, while displacement results of the clinical data show Dice≥0.97 and mean contour distance≤0.464. Additionally, the strain results show correlation coefficient≥0.717. CONCLUSIONS:This study demonstrates that the proposed new method enables to accurately track the motion of the LVM and evaluate strain, which has clinical auxiliary value in the diagnosis of CVD.
Keywords: Left ventricular myocardium, cine magnetic resonance images, biomechanical model, material matrix
DOI: 10.3233/XST-221331
Journal: Journal of X-Ray Science and Technology, vol. 31, no. 3, pp. 525-543, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]