Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Gong, Changchenga; c; * | Shen, Zhaoqiangb | He, Yuanweib
Affiliations: [a] School of Mathematics and Statistics, Chongqing Technology and Business University, Chongqing, China | [b] College of Mathematics and Statistics, Chongqing University, Chongqing, China | [c] Chongqing Key Laboratory of Social Economic and Applied Statistics, Chongqing Technology and Business University, Chongqing, China
Correspondence: [*] Corresponding author: Changcheng Gong, School of Mathematics and Statistics, Chongqing Technology and Business University, Chongqing, 400067, China. E-mail: [email protected].
Abstract: CT reconstruction from incomplete projection data is one of the key researches of X-ray CT imaging. The projection data acquired by few-view and limited-angle sampling are incomplete. In addition, few-view sampling often requires turning on and off the tube voltage, but rapid switching of tube voltage demands for high technical requirements. Limited-angle sampling is easy to realize. However, reconstructed images may encounter obvious artifacts. In this study we investigate a new segmental limited-angle (SLA) sampling strategy, which avoids rapid switching of tube voltage. Thus, the projection data has lower data correlation than limited-angle CT, which is conducive to reconstructing high-quality images. To suppress potential artifacts, we incorporate image structural prior into reconstruction model to present a reconstruction method. The limited-angle CT reconstruction experiments on digital phantoms, real carved cheese and walnut projections are used to test and verify the effectiveness of the proposed method. Several image quality evaluation indices including RMSE, PSNR, and SSIM of the reconstructions in simulation experiments are calculated and listed to show the superiority of our method. The experimental results indicate that the CT image reconstructed using the proposed new method is closer to the reference image. Images from real CT data and their residual images also show that applying the proposed new method can more effectively reduce artifacts and image structures are well preserved.
Keywords: Inverse problems, computed tomography, relative total variation, image sparsity, iterative reconstruction
DOI: 10.3233/XST-221222
Journal: Journal of X-Ray Science and Technology, vol. 30, no. 6, pp. 1127-1154, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]