Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Yang, You-Changa | Wei, Xiao-Yua | Tang, Xiao-Qianga | Yin, Ruo-Hana | Zhang, Minga | Duan, Shao-Fengb; * | Pan, Chang-Jiea; *
Affiliations: [a] Department of Radiology, Changzhou Second People’s Hospital, Changzhou, China | [b] Precision Health Institution, GE Healthcare (China), Shanghai, China
Correspondence: [*] Corresponding authors: Chang-Jie Pan, Department of Radiology, Changzhou Second People’s Hospital, Changzhou, 213000, China. Tel.: +86 13815032301; E-mail: [email protected] and Shao-Feng Duan, Precision Health Institution, GE Healthcare (China), Shanghai, 201203, China. Tel.: +86 18910063803;E-mail: [email protected].
Abstract: PURPOSE:To establish a machine-learning (ML) model based on coronary computed tomography angiography (CTA) images for evaluating myocardial ischemia in patients diagnosed with coronary atherosclerosis. METHODS:This retrospective analysis includes CTA images acquired from 110 patients. Among them, 58 have myocardial ischemia and 52 have normal myocardial blood supply. The patients are divided into training and test datasets with a ratio 7 : 3. Deep learning model-based CQK software is used to automatically segment myocardium on CTA images and extract texture features. Then, seven ML models are constructed to classify between myocardial ischemia and normal myocardial blood supply cases. Predictive performance and stability of the classifiers are determined by receiver operating characteristic curve with cross validation. The optimal ML model is then validated using an independent test dataset. RESULTS:Accuracy and areas under ROC curves (AUC) obtained from the support vector machine with extreme gradient boosting linear method are 0.821 and 0.777, respectively, while accuracy and AUC achieved by the neural network (NN) method are 0.818 and 0.757, respectively. The naive Bayes model yields the highest sensitivity (0.942), and the random forest model yields the highest specificity (0.85). The k-nearest neighbors model yields the lowest accuracy (0.74). Additionally, NN model demonstrates the lowest relative standard deviations (0.16 for accuracy and 0.08 for AUC) indicating the high stability of this model, and its AUC applying to the independent test dataset is 0.72. CONCLUSION:The NN model demonstrates the best performance in predicting myocardial ischemia using radiomics features computed from CTA images, which suggests that this ML model has promising potential in guiding clinical decision-making.
Keywords: Heart, machine learning, computed tomography angiography (CTA), myocardial ischemia
DOI: 10.3233/XST-221160
Journal: Journal of X-Ray Science and Technology, vol. 30, no. 4, pp. 767-776, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]