Article type: Research Article
Authors: Romero, Ignacio O. | Fang, Yile | Li, Changqing; *
Affiliations: Department of Bioengineering, University of California Merced, Merced, CA, USA
Correspondence: [*] Corresponding author: Changqing Li, Department of Bioengineering, University of California Merced, Merced, CA 95343, USA. E-mail: [email protected].
Abstract: BACKGROUND:X-ray image quality relies heavily on the emitted X-ray photon number which depends on X-ray tube current and exposure time. To accurately estimate the absorbed dose in an imaging protocol, it is better to simulate the X-ray imaging with a Monte Carlo platform such as GATE (Geant4 Application for Tomographic Emission). Although input of GATE is the X-ray photon number of the simulated X-ray tube, it lacks a good way to setup the photon number for a desired X-ray tube current setting. OBJECTIVE:To provide a method to correlate the experimental X-ray tube current exposure time and the X-ray photon number in GATE. METHODS:The accumulated radiation dose of a micro-computed tomography (CT) X-ray tube was recorded at different current exposure times with a general-purpose ion chamber. GATE was used to model the experimental microCT imaging system and calculate the total absorbed dose (cGy) in the sensitive volume of the ion chamber with different X-ray photon numbers. Linear regression models are used to establish a correlation between the estimated X-ray photon number and the X-ray tube settings. At first, one model establishes the relationship between the experimentally measured dose and the X-ray tube setting. Then, another model establishes a relationship between the simulated dose and the X-ray number in GATE. At last, by correlating these two models, a regression model to estimate the X-ray output number from an experimental X-ray tube setting (mAs) is obtained. RESULTS:For a typical micro-CT scan, the X-ray tube is operated at 50 kVp and 0.5 mA for a 500 ms exposure time per projection (0.25 mAs). For these X-ray imaging parameters, the X-ray number per projection is estimated to be 3.613×106 with 1.0 mm Al filter. CONCLUSION:The findings of this work provide an approach to correlate the experimental X-ray tube current exposure time to the X-ray photon number in the GATE simulation of the X-ray tube to more accurately determine radiation dose for an imaging protocol.
Keywords: X-ray imaging, GATE, Monte Carlo
DOI: 10.3233/XST-221126
Journal: Journal of X-Ray Science and Technology, vol. 30, no. 4, pp. 667-675, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]