Article type: Research Article
Authors: Xu, Yongshuna | Sushmit, Asifb | Lyu, Qingb | Li, Yingc | Cao, Ximiaoc | Maltz, Jonathan S.c; d; * | Wang, Geb; * | Yu, Hengyonga; *
Affiliations: [a] Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, USA | [b] Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA | [c] Molecular Imaging and Computed Tomography, GE Healthcare, 3000 N Grandview Boulevard, Waukesha, WI, USA | [d] Molecular Biophysics and Integrated Bioimaging, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA, USA
Correspondence: [*] Corresponding authors: J.S. Maltz, Molecular Imaging and Computed Tomography, GE Healthcare, 3000 N Grandview Boulevard, Waukesha, WI, 53188, USA. E-mail: [email protected]; G. Wang, Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180, USA. E-mail: [email protected]; H.Y. Yu, Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, 01854, USA. E-mail: [email protected].
Abstract: Cardiac CT provides critical information for the evaluation of cardiovascular diseases. However, involuntary patient motion and physiological movement of the organs during CT scanning cause motion blur in the reconstructed CT images, degrading both cardiac CT image quality and its diagnostic value. In this paper, we propose and demonstrate an effective and efficient method for CT coronary angiography image quality grading via semi-automatic labeling and vessel tracking. These algorithms produce scores that accord with those of expert readers to within 0.85 points on a 5-point scale. We also train a neural network model to perform fully-automatic motion artifact grading. We demonstrate, using XCAT simulation tools to generate realistic phantom CT data, that supplementing clinical data with synthetic data improves the scoring performance of this network. With respect to ground truth scores assigned by expert operators, the mean square error of grading motion of the right coronary artery is reduced by 36% by synthetic data supplementation. This demonstrates that augmentation of clinical training data with realistically synthesized images can potentially reduce the number of clinical studies needed to train the network.
Keywords: Cardiac CT, motion artifacts, semi-automatic labeling, vessel tracking, deep learning
DOI: 10.3233/XST-211109
Journal: Journal of X-Ray Science and Technology, vol. 30, no. 3, pp. 433-445, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]