Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kim, Gyeong Ripa; 1 | Kim, Sunghob; 1 | Sung, Soon Kia | Kim, Chang Hyeuna | Lee, Sang Bongc | Yoo, Jang Seond | Kwak, Jong Hyeokd; *
Affiliations: [a] Department of Neurosurgery, Pusan National University Yang-san Hospital, Pusan National University School of Medicine, Yang-san, Korea | [b] Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Korea | [c] Department of Hospital and Social cooperation, Good Gangan Hospital, Busan, Korea | [d] Department of Radiology, Pusan National University Yang-san Hospital, Yang-san, Korea
Correspondence: [*] Corresponding author: Jong Hyeok Kwak, Department of Radiology, Pusan National University Yang-San Hospital, Beomeo-ri, Mulgeum-eup, Yangsan-si, Gyeongsangnam-do, Korea. Tel.: +82 10 5520 9476; E-mail: [email protected].
Note: [1] Contributed equally to this work as co-first author.
Abstract: OBJECTIVE:To invastgate feasibility of low-dose contrast agent in cerebral computed tomography angiography (CTA) to alleviate side effects. METHOD:Siemens’ Somatom Definition AS+CT scanner, Heine’s blood pressure monitor G7-M237 (BP cuff) and Ultravist contrast agent (370 mg Iodine/ml) are used. CTA is acquired using following scan parameters including slice thickness of 1mm, image acquisition parameters of 128×0.6 mm, pitch size of 0.8 mm, 175 effective mAs, 120 kVp tube voltage, scan delay time of 3 seconds, and the scan time of 4 seconds. This study is conducted by securing the IV route in the left antecubital vein before injection of contrast agent, wrapping BP cuff around the branchial artery of the opposite right arm after setting the pressure to 200 mmHg. Then, the injection rate of the contrast agent is fixed at 4.5 cc/sec and contrast agent was injected in three different amounts (70, 80, and 100 cc). Bp cuff is released from this moment when HU value reachs 100. RESULT:In this study, the mean HU values measured from common carotid artery are 412.45±5.89 when injecting 80cc contrast agent and using BP cuff and 399.64±5.51 when injecting 100 cc contrast agenet and not using BP cuff, respectively. In middle cerebral artery M1, the mean HU values are 325.23±38.29 when injecting 80cc contrast agent and using BP cuff and 325.00±30.63 when injecting 100cc contrast agent blood and not using pressure cuff, respectively. Difference of mean HU values is not statistically significant (p > 0.05) with and without using BP cuff. CONCLUSION:This study demonstrates that reducing amount of contrast agent is possible when the right brachial artery is compressed using BP cuff. Study results indicate that reducing 20% injection of contrast agent in CT cerebrovascular angiography can still yield comparable imaging results with conventional contrast angent usage, which implies that less side effects are expected with a contrast agent injection. Thus, this study can serve as a reference for potential reducing side effect during CT cerebrovascular angiography.
Keywords: Contrast agent, right brachial artery, blood pressure cuff, computed tomography cerebrovascular angiography
DOI: 10.3233/XST-211022
Journal: Journal of X-Ray Science and Technology, vol. 30, no. 1, pp. 135-144, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]