Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kang, Zhen | Xu, Anhui | Wang, Liang; *
Affiliations: Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Technology and Science, Jiefang Avenue, Wuhan, China
Correspondence: [*] Corresponding author: Liang Wang, Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Technology and Science, #1095, Jiefang Avenue, Wuhan 430030, China. Tel.: +86 83663737; E-mail: [email protected].
Abstract: BACKGROUND:Since Gleason score (GS) 4 + 3 prostate cancer (PCa) has a worse prognosis than GS 3 + 4 PCa, differentiating these two types of PCa is of clinical significance. OBJECTIVE:To assess the predictive roles of using T2WI and ADC-derived image texture parameters in differentiating GS 3 + 4 from GS 4 + 3 PCa. METHODS:Forty-eight PCa patients of GS 3 + 4 and 37 patients of GS 4 + 3 are retrieved and randomly divided into training (60%) and testing (40%) sets. Axial image showing the maximum tumor size is selected in the T2WI and ADC maps for further image texture feature analysis. Three hundred texture features are computed from each region of interest (ROI) using MaZda software. Feature reduction is implemented to obtain 30 optimal features, which are then used to generate the most discriminative features (MDF). Receiver operating characteristic (ROC) curve analysis is performed on MDF values in the training sets to achieve cutoff values for determining the correct rates of discrimination between two Gleason patterns in the testing sets. RESULTS:ROC analysis on T2WI and ADC-derived MDF values in the training set (n = 51) results in a mean area under the curve (AUC) of 0.953±0.025 (with sensitivity 0.9274±0.0615 and specificity 0.897±0.069), and 0.985±0.013 (with sensitivity 0.9636±0.0446 and specificity 0.9726±0.0258), respectively. Using the corresponding MDF cutoffs, 95.3% (ranges from 76.5% to 100%) and 94.1% (ranged from 76.5% to 100%) of test cases (n = 34) are correctly discriminated using T2WI and ADC-derived MDF values, respectively. CONCLUSIONS:The study demonstrates that using T2WI and ADC-derived image texture parameters has a potential predictive role in differentiating GS 3 + 4 and GS 4 + 3 PCa.
Keywords: Classification of prostate cancer, magnetic resonance imaging, gleason score, image texture analysis
DOI: 10.3233/XST-200785
Journal: Journal of X-Ray Science and Technology, vol. 29, no. 2, pp. 307-315, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]