Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Nazia Fathima, S.M.a; * | Tamilselvi, R.a | Parisa Beham, M.a | Sabarinathan, D.b
Affiliations: [a] Department of Electronics and Communication Engineering, Sethu Institute of Technology, Kariapatti, Tamilnadu, India | [b] Couger Inc., Tokyo, Japan
Correspondence: [*] Corresponding author: S.M. Nazia Fathima, Department of Electronics and Communication Engineering, Sethu Institute of Technology, Kariapatti - 626115, Tamilnadu, India. E-mail: [email protected].
Abstract: BACKGROUND:Osteoporosis, a silent killing disease of fracture risk, is normally determined based on the bone mineral density (BMD) and T-score values measured in bone. However, development of standard algorithms for accurate segmentation and BMD measurement from X-ray images is a challenge in the medical field. OBJECTIVE:The purpose of this work is to more accurately measure BMD from X-ray images, which can overcome the limitations of the current standard technique to measure BMD using Dual Energy X-ray Absorptiometry (DEXA) such as non-availability and inaccessibility of DEXA machines in developing countries. In addition, this work also attempts to analyze the DEXA scan images for better segmentation and measurement of BMD. METHODS:This work employs a modified U-Net with Attention unit for accurate segmentation of bone region from X-Ray and DEXA images. A linear regression model is developed to compute BMD and T-score. Based on the value of T-score, the images are then classified as normal, osteopenia or osteoporosis. RESULTS:The proposed network is experimented with the two internally collected datasets namely, DEXSIT and XSITRAY, comprised of DEXA and X-ray images, respectively. The proposed method achieved an accuracy of 88% on both datasets. The Dice score on DEXSIT and XSITRAY is 0.94 and 0.92, respectively. CONCLUSION:Our modified U-Net with attention unit achieves significantly higher results in terms of Dice score and classification accuracy. The computed BMD and T-score values of the proposed method are also compared with the respective clinical reports for validation. Hence, using the digitized X-Ray images can be used to detect osteoporosis efficiently and accurately.
Keywords: Osteoporosis, bone mineral density (BMD), dual-energy X-ray absorptiometry (DEXA), deep learning, attention unit, U-net, Dice value, and T-Score
DOI: 10.3233/XST-200692
Journal: Journal of X-Ray Science and Technology, vol. 28, no. 5, pp. 953-973, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]