Article type: Research Article
Authors: Hsiao, Chia-Chia | Chen, Po-Choub | Kuo, Pei-Chib | Ho, Chih-Haoc | Jao, Jo-Chid; *
Affiliations: [a] Department of Radiology, Kaohsiung Veterans General Hospital, Taiwan, R.O.C | [b] Department of Biomedical Engineering, I-Shou University, Taiwan, R.O.C | [c] Department of Medical Imaging, Taipei City Hospital (Yangming Branch), Taiwan, R.O.C | [d] Department of Medical Imaging and Radiological Sciences, College of Health Sciences, Kaohsiung Medical University, Taiwan, R.O.C
Correspondence: [*] Corresponding author: Jo-Chi Jao, Ph.D. (80708) No. 100, Shih-Chuan 1st Rd., Sanmin Dist., Kaohsiung City, Taiwan, R.O.C. Tel.: +886 7 3121101 ext. 2356 14; Fax: +886 7 3113449; E-mail: [email protected].
Abstract: BACKGROUND:Although computed tomography (CT) is a powerful diagnostic imaging modality for diagnosing vascular diseases, it is some what risky to human health due to the high radiation dosage. Thus, CT vendors have developed low dose computed tomography (LDCT) aiming to solve this problem. Nowadays, LDCT has gradually become a main stream of CT examination. OBJECTIVE:This study aimed to assess the feasibility of LDCTAin an animal model and compare the imaging features and doses in two clinical scanners. METHODS:Twenty-two New Zealand rabbit head and neck CTA images pre- and post-contrast agent injection were performed using256-sliceand 64-slice CT scanners. The tube voltages used in the 256-slice and the 64-slice CTA were 70 kVp and 80 kVp, respectively. Quantitative images indices and radiation doses obtained from CTA in these two scanners were compared. RESULTS:More neck arterial vessels could be visualized in multi-planar reconstruction (MPR) CTA on the 256-slice CT scanner than on the 64-slice CT scanner. After contrast agent injection, all observed neck arterial vessels had higher CT numbers in 256-slice CTA than in 64-slice CTA. There was no significant difference in contrast-to-noise (CNR) of CTA images between these two scanners. CT dose index (CTDI) and dose length product (DLP) for the 256-slice CTA were lower than those for the 64-slice CTA. CONCLUSIONS:Low dose CTA of rabbits with 70 or 80 kVp is feasible in a 256-slice or a 64-slice CT scanner. The radiation dose from the 256-slice CTA was much lower than that from the 64-slice CTA with comparable SNR and CNR. The technique can be further applied in longitudinal monitoring of an animal stroke model in the future.
Keywords: Low dose computed tomography angiography, 256-slice CTA, 64-slice CTA, New Zealand rabbit model, CT number, signal-to-noise ratio, contrast-to-noise ratio
DOI: 10.3233/XST-200669
Journal: Journal of X-Ray Science and Technology, vol. 28, no. 4, pp. 739-750, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]