Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Tan, Lua | Liang, Antonia; * | Li, Linga | Liu, Wanquana | Kang, Hanwenb | Chen, Chaob
Affiliations: [a] School of Electrical Engineering, Computing and Mathematical Sciences (Computing Discipline), Curtin University, Bentley, Western Australia, Australia | [b] Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC, Australia
Correspondence: [*] Corresponding author: Antoni Liang PhD, School of Electrical Engineering, Computing and Mathematical Sciences (Computing Discipline), Curtin University, Bentley, Western Australia, 6102, Australia. E-mail: [email protected].
Abstract: BACKGROUND:Segmentation of prostate from magnetic resonance images (MRI) is a critical process for guiding prostate puncture and biopsy. Currently, the best results are obtained by Convolutional Neural Network (CNN). However, challenges still exist when applying CNN to segment prostate, such as data distribution issue caused by insubstantial and inconsistent intensity levels and vague boundaries in MRI. OBJECTIVE:To segment prostate gland from a MRI dataset including different prostate images with limited resolution and quality. METHODS:We propose and apply a global histogram matching approach to make intensity distribution of the MRI dataset closer to uniformity. To capture the real boundaries and improve segmentation accuracy, we employ a module of variational models to help improve performance. RESULTS:Using seven evaluation metrics to quantify improvements of our proposed fusion approach compared with the state of art V-net model resulted in increase in the Dice Coefficient (11.2%), Jaccard Coefficient (13.7%), Volumetric Similarity (12.3%), Adjusted Rand Index (11.1%), Area under ROC Curve (11.6%), and reduction of the Mean Hausdorff Distance (16.1%) and Mahalanobis Distance (2.8%). The 3D reconstruction also validates the advantages of our proposed framework, especially in terms of smoothness, uniformity, and accuracy. In addition, observations from the selected examples of 2D visualization show that our segmentation results are closer to the real boundaries of the prostate, and better represent the prostate shapes. CONCLUSIONS:Our proposed approach achieves significant performance improvements compared with the existing methods based on the original CNN or pure variational models.
Keywords: Automatic prostate segmentation, convolutional neural networks, variational models
DOI: 10.3233/XST-190524
Journal: Journal of X-Ray Science and Technology, vol. 27, no. 5, pp. 821-837, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]