Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kurtul, Neslihana; * | Yurttutan, Nurselb | Baykara, Muratb
Affiliations: [a] Department of Radiation Oncology, Sutcu Imam University Faculty of Medicine, Kahramanmaras, Turkey | [b] Department of Radiology, Sutcu Imam University Faculty of Medicine, Kahramanmaras, Turkey
Correspondence: [*] Corresponding author: Neslihan Kurtul, Department of Radiation Oncology, Sutcu Imam University Faculty of Medicine, Avsar campus, Kahramanmaras, Turkey. Tel.: +90 506 787 28 41; E-mail: [email protected].
Abstract: OBJECTIVE:The aim of this study was to apply texture analysis to investigate whether there was a change in the lens following radiotherapy. PATIENTS AND METHOD:Patients who received radiotherapy (RT) for head and neck cancer or brain tumor were enrolled. Computed tomography (CT) images taken in the last month before RT and the most recent images after RT were compared. Entropy values were calculated using lens attenuation values. The lens doses were obtained from the dose-volume histogram data. RESULTS:A total of 55 lenses were evaluated. The mean Hounsfield Unit value of the lenses was 66.14±12.16 before RT and 72.02±9.12 after RT (p = 0.007). The mean entropy value was 1.87±0.31 before RT and this reduced to 1.31±0.34 after RT (p < 0.001), respectively. As time increased, the difference in entropy also increased (p = 0.007). A correlation close to statistical significance was determined between the entropy difference and minimum, maximum and mean lens radiation dose (p = 0.052, p = 0.052, p = 0.063, respectively). The entropy difference was significantly reduced in the >4 Gy group (p = 0.046). CONCLUSION:Study results indicated that the entropy values in the lens were signifcantly changed after radiotherapy and the degree of the change associated with dose and time.
Keywords: Entropy, lens, radiotherapy, texture analysis
DOI: 10.3233/XST-18373
Journal: Journal of X-Ray Science and Technology, vol. 26, no. 5, pp. 747-755, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]