Article type: Research Article
Authors: Kesen, Nazmiye Donmez; * | Akbas, Ugur | Koksal, Canan | Bilge, Hatice
Affiliations: Division of Medical Physics, Istanbul University Oncology Institute, Istanbul, Turkey
Correspondence: [*] Corresponding author: Dr. Nazmiye Donmez Kesen, Division of Medical Physics, Istanbul University Oncology Institute, Istanbul, Turkey. Tel.: +90 536 916 7516; E-mail:[email protected].
Abstract: In radiotherapy, dose distributions are obtained by using dose calculation algorithms that are implanted in treatment planning systems (TPS). This study aims to compare the surface doses of separate field sizes calculated by different version of The Analytical Anisotropic Algorithm (AAA) and measured by the parallel-plate ion chamber that is admitted as the most reliable dosimetry system for the surface region dose measurements. In order to measure the near surface dose, water equivalent solid phantom was used and measurements were made for 6MV photon beam at 100 cm source-detector distance for 5×5, 10×10, and 20×20 cm2 field sizes. AAA 8.9 and AAA 15.1 versions of the Varian Eclipse TPS were used for surface dose calculations by generating beams with separate field sizes. The doses were read by considering the effective buildup thickness of Markus parallel-plate ion chamber. The surface doses using 6 MV photon beams for 10×10 cm2 field size at 0.07 mm were found to be 11.04%, 26.25%, and 19.69% for AAA v8.9, AAA v15.1 and Markus chamber, respectively. It was seen that for both of the AAA versions and Markus parallel-plate ion chamber, increasing field sizes also increase surface dose. For all field sizes, surface dose was lowest by using AAA v8.9 at 0.07 mm. The different versions of the same TPS algorithms may calculate the surface doses distinctively. After upgrading of TPS algorithms, surface doses should be calculated and compared by measurements with different dosimetry systems to better understand their calculation behaviors in the near surface region.
Keywords: AAA dose algorithm, surface dose, buildup region, Markus parallel plate ion chamber
DOI: 10.3233/XST-180489
Journal: Journal of X-Ray Science and Technology, vol. 27, no. 2, pp. 361-369, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]